Rapid determination of phenylalanine and tyrosine in volumetrically collected dried blood spots using fully automated processing and analysis by capillary electrophoresis

被引:2
作者
Aranda-Merino, Noemi [1 ,2 ]
Dvorak, Milos [2 ]
Kuban, Pavel [2 ]
机构
[1] Univ Seville, Fac Chem, Dept Analyt Chem, Prof Garcia Gonzalez S-N, Seville 41012, Spain
[2] Czech Acad Sci, Inst Analyt Chem, Veveri 97, CZ-60200 Brno, Czech Republic
关键词
Automation; Amino acids; Dried blood spots; Capillary electrophoresis; Short-end injection; Volumetric microsampling; Rapid analysis; AMINO-ACIDS; THIAMINE STATUS; PHENYLKETONURIA; DIAGNOSIS; SAMPLES; MS/MS;
D O I
10.1016/j.talanta.2024.127253
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An off-the-shelf Agilent 7100 capillary electrophoresis (CE) instrument was employed for the automated processing and analysis of dried blood spots (DBSs) collected by Capitainer (R) B volumetric devices. Solutions for DBS elutions were transferred directly into CE vials through a separation capillary by the application of an auxiliary nitrogen gas connected to the external pressure line of the CE instrument. This allowed for liquid handling at pressures up to 15 bar and enabled the use of a single capillary for rapid DBS processing and efficient CE separations. The resulting DBS eluates were at-line injected into a short capillary end, which served for improved instrumental simplicity and short CE analysis times. The current set-up necessitated neither hardware nor software adjustments of the CE instrument, except for the connection of a gas cylinder to an in-built connector. The novel features presented in this study (DBSs with exact blood volumes, high external pressures, and short-end injections) were used for the automated determination of clinically relevant markers, phenylalanine (Phe) and tyrosine (Tyr), in DBS samples. Sensitive and selective Phe and Tyr quantification was achieved by CE-UV in 375 mM formic acid and 0.01 % (v/v) Tween 20 (pH 2.09) as a background electrolyte. The total processing and analysis times per one DBS were <1.5 and 4.5 min, respectively, in a sequence of 36 DBSs, and resulted in a sample throughput of >10 DBSs per hour. The intra- and inter-day repeatability values were better than 5.9 and 1.1 % RSD for peak areas and migration times, respectively, and calibration curves were linear in the 20-3000 mu M (Phe) and 20-250 mu M (Tyr) range (R-2 >= 0.9973). The limits of detection were <= 2 mu M and enabled the determination of endogenous Phe and Tyr concentrations as well as elevated Phe concentrations and Phe/Tyr ratios, which are the typical markers for neonatal phenylketonuria screening.
引用
收藏
页数:11
相关论文
共 49 条
[11]   Automated Sequential Injection-Capillary Electrophoresis for DriedBlood Spot Analysis: A Proof-of-Concept Study [J].
Dvorak, Milos ;
Miro, Manuel ;
Kuban, Pavel .
ANALYTICAL CHEMISTRY, 2022, 94 (13) :5301-5309
[12]  
ema, US
[13]   Implementing Dried Blood Spot Sampling for Clinical Pharmacokinetic Determinations: Considerations from the IQ Consortium Microsampling Working Group [J].
Evans, Christopher ;
Arnold, Mark ;
Bryan, Peter ;
Duggan, Jeffrey ;
James, Christopher A. ;
Li, Wenkui ;
Lowes, Steve ;
Matassa, Luca ;
Olah, Timothy ;
Timmerman, Philip ;
Wang, Xiaomin ;
Wickremsinhe, Enaksha ;
Williams, John ;
Woolf, Eric ;
Zane, Patricia .
AAPS JOURNAL, 2015, 17 (02) :292-300
[14]   Application of short-end injection procedure in CE [J].
Glatz, Zdenek .
ELECTROPHORESIS, 2013, 34 (05) :631-642
[15]  
GUTHRIE R, 1963, PEDIATRICS, V32, P338
[16]   A fast high performance liquid chromatographic (HPLC) analysis of amino acid phenylketonuria disorder in dried blood spots and serum samples, employing C18 monolithic silica columns and photo diode array detection [J].
Haghighi, Farideh ;
Talebpour, Zahra ;
Amini, Vali ;
Ahmadzadeh, Amir ;
Farhadpour, Mohsen .
ANALYTICAL METHODS, 2015, 7 (18) :7560-7567
[17]   Phenylketonuria: translating research into novel therapies [J].
Ho, Gladys ;
Christodoulou, John .
TRANSLATIONAL PEDIATRICS, 2014, 3 (02) :49-62
[18]   Measuring thiamine status in dried blood spots [J].
Huang, Yichao ;
Gibson, Robert A. ;
Green, Timothy J. .
CLINICA CHIMICA ACTA, 2020, 509 :52-59
[19]   Amino acid analysis of dried blood spots for diagnosis of phenylketonuria using capillary electrophoresis-mass spectrometry equipped with a sheathless electrospray ionization interface [J].
Jeong, Ji-Seon ;
Kim, Sook-Kyung ;
Park, Sang-Ryoul .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (25) :8063-8072
[20]   Determination of phenylalanine in blood by high-performance anion-exchange chromatography-pulsed amperometric detection to diagnose phenylketonuria [J].
Jeong, Ji-Seon ;
Sim, Hee-Jung ;
Lee, Yong-Moon ;
Yoon, Hye-Ran ;
Lee, Dong Hwan ;
Hong, Seon-Pyo .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (30) :5709-5714