Deposition characteristics of electrostatic spraying by negative high-voltage corona discharge

被引:0
|
作者
Jiangsu University, Zhenjiang 212013, China [1 ]
机构
来源
Gaodianya Jishu | 2008年 / 11卷 / 2440-2446期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Electrostatic spraying is a new technology for improving pesticide deposition to reduce environmental pollution. In this paper, simulative plants were used instead of real plants to perform electrostatic and traditional spraying comparative experiments. The deposition mass and density were measured by colorimetry, gravimetric method and microscope slides counting method respectively both under electrostatic and traditional spraying technology. It was found electrostatic spraying technology provided droplets with much better characteristics of atomization, uniformity, penetrability and attachment. And the deposition mass in electrostatic spraying raised 10%-30% than that in traditional spraying and the deposition density raised 1-2 times. It could improve the distributing characteristic further, especially on the backs and lower leaves. Consequently, the probability of killing insects is increased and the drift of pesticide is reduced greatly. And the most ideal charging voltage is 18-20 kV.
引用
收藏
相关论文
共 50 条
  • [1] Experimental study on electrostatic spraying of negative high-voltage pulse corona charge
    Chen, Zhigang
    Zhou, Jinmu
    Wu, Chundu
    Chu, Jinyu
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (02): : 128 - 131
  • [2] Experimental analysis on electrostatic atomization of negative high-voltage corona discharge
    Li, Qing
    Sun, Xiao-Rong
    Li, Hai-Feng
    Zhang, Wen-Yue
    Wang, Ji-Guang
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (06): : 1520 - 1524
  • [3] Optimal high-voltage energization of corona electrostatic separators
    Iuga, A
    Neamtu, V
    Suarasan, I
    Morar, R
    Dascalescu, L
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (02) : 286 - 293
  • [4] Discharge characteristics and applications for electrostatic precipitation of direct current: corona with spraying discharge electrodes
    Xu, DX
    Li, J
    Wu, Y
    Wang, LH
    Sun, DW
    Liu, ZY
    Zhang, YB
    JOURNAL OF ELECTROSTATICS, 2003, 57 (3-4) : 217 - 224
  • [5] Corona characteristics of high-voltage transmission line
    Xie, Shuyong
    Wang, Yun
    Gaoya Dianqi/High Voltage Apparatus, 1996, 32 (05): : 20 - 22
  • [6] Electrostatic discharge effects on the high-voltage solar array
    Electromagnetic Environment Effect Key Laboratory, Mechanical Engineering College, Shijiazhuang 050003, China
    Yuan, Q., 1600, Science Press (39):
  • [7] HIGH-VOLTAGE CORONA
    KINDIJ, E
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1969, 21 (02): : 30 - &
  • [8] Measurement of agricultural high-voltage electrostatic spraying field by using PDPA
    Jia, Weidong
    Qiu, Baijing
    Shi, Aiping
    Mei, Guohua
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2007, 38 (12): : 66 - 69
  • [9] HIGH-VOLTAGE TRAVELING WAVES WITH CORONA DISCHARGE ON BUNDLED CONDUCTORS
    INOUE, A
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (04): : 1010 - 1010
  • [10] The influence of high-voltage pulse parameters on corona current in electrostatic precipitators
    Klippel, N
    JOURNAL OF ELECTROSTATICS, 2000, 49 (1-2) : 31 - 49