Measurement and simulation of disturbance voltage generated by VFTO in UHV GIS substation on the secondary cables

被引:0
|
作者
机构
[1] Zhang, Weidong
[2] Chen, Peilong
[3] Chen, Weijiang
[4] Cui, Xiang
[5] Wang, Lei
[6] Huang, Huimin
[7] Hu, Rong
[8] Wu, Chaofei
来源
Zhang, W. (zwd@ncepu.edu.cn) | 1600年 / Chinese Society for Electrical Engineering卷 / 33期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 23 条
  • [1] Simulation research on VFTO waveform attenuation in UHV GIS substation
    Wang L.
    Liu Y.
    Feng Y.
    Wang H.
    Zhao J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (22): : 45 - 51
  • [2] Study on VFTO of XiMeng UHV substation 1000kV GIS substation
    Su, Xiu-Cheng
    Liu, Bo-Han
    Bo, Li
    Yan, Guo-Zeng
    Ni, Xiang-Ping
    Liu, Zhen-Tao
    PROCEEDINGS OF THE 2ND ANNUAL INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL ENGINEERING AND INFORMATION SCIENCE (EEEIS 2016), 2016, 117 : 335 - 341
  • [3] Development of Full Frequency Bandwidth Measurement of VFTO in UHV GIS
    Yue Gongchang
    Liu Weidong
    Chen Weijiang
    Guan Yonggang
    Li Zhibing
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) : 2550 - 2557
  • [4] Experimental Research and Simulation on VFTO Mitigation by Ferrite Rings in UHV GIS
    He, Jiaxi
    Guan, Yonggang
    Chen, Weijiang
    Liu, Weidong
    Jin, Guangyao
    Li, Xinyi
    Dai, Min
    Cai, Yuanji
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 940 - 948
  • [5] Simulation of VFTO Suppression Methods for 1100kV GIS Substation
    Gong, Wenxiu
    Wang, Peijin
    Li, Qingquan
    Xue, Weijian
    Qiao, Mu
    Wang, Xiao
    Pang, Yumei
    PROCEEDINGS OF 2019 IEEE 3RD INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC 2019), 2019, : 987 - 991
  • [6] Research on Disturbance Voltage of Secondary Cables Due to a Circuit Breaker Ground Fault in UHVDC Convertor Substation
    Yan, Lei
    Zhang, Weidong
    Zhang, Zhaohua
    Shi, Weidong
    Kang, Peng
    Shi, Lei
    2018 IEEE SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL INTEGRITY AND POWER INTEGRITY (EMC, SI & PI), 2018,
  • [7] Frequency domain algorithm in the whole process simulation from VFTO to its conducted disturbance via voltage transformer in GIS substations
    Zhao, Jun
    Chen, Weijiang
    Li, Kejie
    Wan, Baoquan
    Zhang, Jiangong
    Wen, Tao
    Zhang, Xiaoli
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 209
  • [8] Analysis of Conducted Disturbance via Current Transformer Due to Switch Operation of GIS Disconnector in UHV Substation
    Zhao, Jun
    Chen, Weijiang
    Li, Kejie
    Teng, Zihan
    Li, Ni
    Wen, Tao
    Fan, Xing
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (03): : 1227 - 1234
  • [9] Time Frequency Characteristic Analysis and Simulation of VFTO Waveform Generated by Disconnector Switch in GIS
    Zhou Kaifeng
    Hu Yue
    Li Haitao
    Xue Feng
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 194 - 197
  • [10] Study of Transient Enclosure Voltage Coupling to Secondary Cables in a Gas-Insulated Substation
    Cai, Yuanji
    Guan, Yonggang
    Liu, Weidong
    He, Jiaxi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) : 761 - 768