Protection of Longitudinal Power-Supply Lines from the Electromagnetic Impact of a Traction Network

被引:0
|
作者
Bader, M.P. [1 ]
Ermolenko, D.V. [1 ]
Kulikov, A.A. [1 ]
机构
[1] Russian University of Transport, Moscow
关键词
electromagnetic impact; longitudinal power-supply lines; traction network; voltage asymmetry; wire transposition;
D O I
10.3103/S1068371224700950
中图分类号
学科分类号
摘要
Abstract: Simulation and investigation have been performed for the electromagnetic impact of the traction network exerted on the adjacent longitudinal power-supply line in an open-circuit mode, in a loading mode when there is an electric rolling stock on the stretch, and in a short-circuit mode of the traction network. The simulation of electromagnetic impact has been performed with the use of a method of mirror images, for which it is necessary to solve the D’Alembert equations in cylindrical coordinates. The analysis and synthesis of the asymmetry in voltages and linear electrical parameters in phase wires, resulting from the electromagnetic impact of the traction network, indicates a possible excess in the rated values according to GOST (State Standard) 32144-2013, especially under conditions when the high-voltage line is mounted on the supports of the contact network. Methods are proposed for reducing the asymmetry of the electrical parameters of an overhead longitudinal power-supply line originating from the electromagnetic impact of the traction network. The protection of longitudinal power-supply lines from the electromagnetic impact of the traction network based on the transposition of the wires of an overhead high-voltage power-supply line is considered most efficient. © Allerton Press, Inc. 2024.
引用
收藏
页码:757 / 762
页数:5
相关论文
共 5 条
  • [1] Research on the longitudinal protection of a through-type cophase traction direct power supply system based on the empirical wavelet transform
    Li, Lu
    Zhang, Zeduan
    Cai, Wang
    Zhuang, Qikang
    Bi, Guihong
    Deng, Jian
    Chen, Shilong
    Kan, Xiaorui
    GLOBAL ENERGY INTERCONNECTION-CHINA, 2024, 7 (02): : 206 - 216
  • [2] Scheme of Long Distance Power Supply for Electrified Railway Traction Network Based on Traction Cable
    Wang H.
    Li Q.
    Liu W.
    Wang C.
    Liu T.
    Zhongguo Tiedao Kexue/China Railway Science, 2021, 42 (01): : 137 - 146
  • [3] Boundary frequency characteristic study of traction network in continuous co-phase AT traction power supply system
    Chen S.
    Yang H.
    Bi G.
    Zhao S.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (06): : 192 - 198
  • [4] Electromagnetic Effect of an Alternating Current Traction Power Supply System with a High-Voltage Power Cord on Electrical Installations and Networks of Nontraction Consumers
    Kosarev A.B.
    Kosarev B.I.
    Russian Electrical Engineering, 2020, 91 (02) : 128 - 134
  • [5] Improvement of distance protection of overhead transmission lines rated over 1000 v having self-supporting insulated wires under electromagnetic impact of railroad AC networks
    Kosarev B.I.
    Serbinenko D.V.
    Kuznetsov D.G.