Control Strategy Optimization of Thermodynamic Venting System in Liquid Hydrogen Storage Tank Under Microgravity

被引:0
作者
Hui Chen [1 ]
Xiaolong Li [1 ]
Haomai Zhang [1 ]
Peng Yang [1 ]
Yingwen Liu [1 ]
Wenlian Ye [2 ]
Chunjie Yan [3 ]
Xiaojun Wang [3 ]
机构
[1] Key Laboratory of Thermo-Fluid Science and Engineering of MOE, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an
[2] College of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou
[3] Science and Technology On Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou
基金
中国国家自然科学基金;
关键词
Control strategy; Cooling capacity utilization; Daily evaporation rate; Liquid hydrogen storage; Thermodynamic venting system (TVS);
D O I
10.1007/s12217-024-10156-2
中图分类号
学科分类号
摘要
This study employed a lumped vapor model to investigate the depressurization dynamics during the thermodynamic venting process in a cryogenic liquid hydrogen storage tank under microgravity conditions. The effects of different control strategies-such as flow distribution, circulation flow rate, spray angle, and throttle valve switching time-on the performance of the thermodynamic venting system (TVS) were studied. Building on this foundation, the control strategies are refined across various filling rates and heat loads. The findings indicate that directing the flow towards the upper nozzle proximate to the vapor enhances the depressurization rate and augments the utilization of cooling capacity. The optimal circulation flow rate matches the heat entering the air pillow, and increases with higher heat load and lower filling rate. When the injection angle is 60°, the TVS achieves optimal performance with the fastest depressurization rate and no thermal stratification. The throttle valve opens during the early depressurization stage and closes when the pressure drops to the critical pressure Pcr, resulting in better performance. A lower filling rate and higher heat load lead to an increase in Pcr. This study provides a solid foundation for optimizing TVS control under various conditions, ultimately extending the storage duration of propellants in orbit. © The Author(s), under exclusive licence to Springer Nature B.V. 2024.
引用
收藏
相关论文
共 30 条
  • [1] Cecere D., Giacomazzi E., Ingenito A., A review on hydrogen industrial aerospace applications, Int. J. Hydrogen Energy, 39, 20, pp. 10731-10747, (2014)
  • [2] Chato D., Cryogenic Technology Development for Exploration Missions//45Th AIAA Aerospace Sciences Meeting and Exhibit, (2007)
  • [3] Dunn S., Hydrogen future: toward a sustainable energy system, Int. J. Hydrogen Energy, 27, 3, pp. 235-264, (2002)
  • [4] Flachbart R.H., Hastings L.J., Hedayat A., Et al., Testing the effects of helium pressurant on thermodynamic vent system performance with liquid hydrogen, AIP Conf. Proc, 985, pp. 1483-1490, (2008)
  • [5] Hedayat A., Hastings L.J., Flachbart R.H., Test data analysis of a spray bar zero-gravity liquid hydrogen vent system for upper stages, AIP Conf. Proc, 710, pp. 1171-1178, (2004)
  • [6] Hedayat A., Bailey J., Hastings L.J., Thermodynamic venting system (TVS) modeling and comparison with liquid hydrogen test data//39th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit, (2003)
  • [7] Imai R., Nishida K., Kawanami O., Et al., Ground based experiment and numerical calculation on thermodynamic vent system in propellant tank for future cryogenic propulsion system, Cryogenics, 109, (2020)
  • [8] Imai R., Nishida K., Kawanami O., Et al., Basic study on thermodynamic vent system in propulsion system for future spacecraft, Microgravity Sci. Technol, 32, pp. 339-348, (2020)
  • [9] Kassemi M., Kartuzova O., Effect of interfacial turbulence and accommodation coefficient on CFD predictions of pressurization and pressure control in cryogenic storage tank, Cryogenics, 74, pp. 138-153
  • [10] Li Z.G., Zhu Z.Q., Liu Q.S., Et al., Simulating propellant reorientation of vehicle upper stage in microgravity environment, Microgravity Sci. Technol, 25, 4, pp. 237-241, (2013)