Novel distributed lightning fault location method for transmission line based on non-contact measurement device of lightning current

被引:0
|
作者
Yao, Chenguo [1 ]
Wu, Hao [1 ,3 ]
Wang, Qi [1 ]
Long, Yi [1 ]
Ma, Yi [2 ]
Shen, Yuan [2 ]
机构
[1] State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing,400030, China
[2] Electric Power Research Institute, Yunnan Electric Power Test Research Institute (Group) Co., Ltd., Kunming,650217, China
[3] Nanjing Power Supply Company, Nanjing,210019, China
来源
关键词
D O I
10.13336/j.1003-6520.hve.2014.09.039
中图分类号
学科分类号
摘要
引用
收藏
页码:2894 / 2902
相关论文
共 50 条
  • [1] Non-contact measurement of lightning current in transmission line based on differential loop
    Yao, Chen-Guo
    Xiao, Qian-Bo
    Long, Yi
    Li, Cheng-Xiang
    Sima, Wen-Xia
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (01): : 43 - 51
  • [2] Location Accuracy Method of Distributed Fault Monitoring Device for Lightning Strike Fault
    Li, Lianlian
    Gu, Shanqiang
    Meng, Gang
    Li, Jian
    Zheng, Lei
    Feng, Zhihui
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (09): : 4110 - 4119
  • [3] Fault location in overhead transmission line: A novel non-contact measurement approach for traveling wave-based scheme
    Anane, Paul Oswald Kwasi
    Huang, Qi
    Bamisile, Olusola
    Ayimbire, Patrick Nyaaba
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 133
  • [4] Lightning fault location and recognition technologies in transmission line
    Peng, Yong
    Wang, Zhi-Xin
    Chen, Jun
    Liu, Kai
    Hu, Jian-Xun
    Wu, Tian
    Liu, Ting
    Xiao, Bin
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (02): : 406 - 410
  • [5] Distributed Lightning Current Monitoring and Its Application to Lightning Protection on Transmission Line
    Lu Yong-ling
    Liu Yang
    Zhou Zhi-cheng
    Lei Meng-fei
    Zhao Chun
    Lu En-ze
    2013 2ND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND MEASUREMENT, SENSOR NETWORK AND AUTOMATION (IMSNA), 2013, : 833 - 836
  • [6] Non-direct lightning current measurement for lightning location systems calibration
    Silvino, JL
    Mesquita, CR
    Visacro, SF
    ELECTRONICS LETTERS, 2003, 39 (06) : 504 - 505
  • [7] Design and implementation of a non-contact magnetic field measurement based fault location system for overhead transmission line
    Huang, Qi
    Yao, Ruoting
    Li, Fuchao
    Zhen, Wei
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA 2013), 2013,
  • [8] Non-Contact Measurement and Polarity Discrimination-Based Identification Method for Direct Lightning Strokes
    Jiang, Kaihua
    Du, Lin
    Chen, Huan
    Yang, Feng
    Wang, Yubo
    ENERGIES, 2019, 12 (02)
  • [9] A Non-Contact Electro-optic Sensor for Lightning Overvoltage Measurement
    Han, Rui
    Yang, Qing
    Sima, Wenxia
    Yuan, Tao
    Dong, Heng
    Sun, Shangpeng
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1147 - 1150
  • [10] Optimization of Transmission-Line Route Based on Lightning Incidence Reported by the Lightning Location System
    Li, Yongfu
    Yang, Qing
    Sima, Wenxia
    Li, Jiaqi
    Yuan, Tao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1460 - 1468