Online measuring of zero-sequence parameters for coupled double-circuit transmission line

被引:4
|
作者
机构
[1] Liang, Zhirui
[2] Gong, Ruibang
[3] Niu, Shengsuo
[4] Zhao, Fei
[5] Zhang, Siwei
来源
Liang, Z. (Zhiruil@sohu.com) | 1600年 / Electric Power Automation Equipment Press卷 / 33期
关键词
Circuit modeling - Distributed parameter - Lumped parameter - Online measuring - Zero sequence parameter;
D O I
10.3969/j.issn.1006-6047.2013.07.012
中图分类号
学科分类号
摘要
The structure of coupled double-circuit transmission line is analyzed and its circuit model of zero- sequence distributed parameters and double-∏-shaped circuit model of zero-sequence lumped parameters are built. By combining the increment method with the double-∏-shaped circuit model, an algorithm is developed for the online measuring of zero-sequence lumped parameters. The conversion relationship between zero-sequence lumped parameters and distributed parameters is deduced, based on which, an algorithm is proposed for the online measuring of distributed parameters. Simulative experiments are carried out for 500 kV coupled double-circuit transmission line with different lengths. The simulative results show that the proposed circuit model and online measuring algorithms are applicable to the online measuring of power system zero-sequence parameters.
引用
收藏
相关论文
共 50 条
  • [1] New Approach for Precisely Measuring the Zero-Sequence Parameters of Long-Distance Double-Circuit Transmission Lines
    Hu, Zhijian
    Xiong, Min
    Li, Chuanqi
    Tang, Peng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) : 1627 - 1635
  • [2] New Method of Measuring the Zero Sequence Parameters of Double-Circuit EHV/UHV Transmission Lines
    Li, Chuanqi
    Hu, Zhijian
    Jiang, Meiling
    Zhang, Ziyong
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [3] Adaptive zero sequence compensation algorithm for double-circuit transmission line protection
    Seyedi, Heresh
    Teimourzadeh, Saeed
    Nezhad, Peyman Soleiman
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (06) : 1107 - 1116
  • [4] Zero sequence behaviour of a double-circuit overhead line
    Benato, Roberto
    Sessa, Sebastian Dambone
    Guglielmi, Fabio
    Partal, Ertugrul
    Tleis, Nasser
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 116 : 419 - 426
  • [5] Zero Sequence Behaviour of a Double-Circuit Overhead Line
    Benato, Roberto
    Sessa, Sebastian Dambone
    Guglielmi, Fabio
    Partal, Ertugrul
    Tleis, Nasser
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [6] Equivalent PI Circuit for Zero-sequence Double Circuit Transmission Lines
    Kang, Ning
    Liao, Yuan
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [7] Operational Analysis of Zero-Sequence Inverse-Time Overcurrent Protection in Parallel Double-Circuit Transmission Lines
    Zhang, Zijin
    Cong, Wei
    Gai, Wuyang
    Wang, Anning
    Xiao, Jing
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 491 - 495
  • [8] Zero-Sequence Voltages of UHV Untransposed Double-Circuit Lines and Their Influence on Pilot Protection
    Liao, Huiqin
    Li, Bin
    Li, Zhongqing
    Du, Dingxiang
    Jiang, Xianguo
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 846 - 851
  • [9] Double-circuit transmission line based on interconnection of sequence networks
    Li, Botong
    Li, Yongli
    Li, Hongbo
    Su, Bin
    Li, Youyi
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (09): : 53 - 58
  • [10] ZERO-SEQUENCE CURRENT DISTRIBUTION FOR DOUBLE CIRCUIT TRANSMISSION-LINE WITH SINGLE GROUND WIRE
    KHALEK, MGA