Combined effect of refrigerant amount reduction and composition change on heat pump system performance during refrigerant mixture leakage

被引:0
|
作者
Jeong, Yeonwoo [1 ]
Lee, Sangwook [2 ]
Menegazzo, Davide [3 ]
Lombardo, Giulia [3 ]
Bobbo, Sergio [3 ]
Fedele, Laura [3 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Dept Mech Engn, Seoul 08826, South Korea
[2] Chung Ang Univ, Sch Energy Syst Engn, Seoul 06974, South Korea
[3] CNR, Construct Technol Inst, I-35127 Padua, Italy
关键词
Refrigerant leakage; Zeotropic mixture; Heat pump system; Composition change; Refrigerant amount reduction; Coefficient of performance; R32; R1234ZE(E); R1234YF; ALTERNATIVES; R134A; HYDROCARBONS; TEMPERATURE;
D O I
10.1016/j.applthermaleng.2024.124691
中图分类号
O414.1 [热力学];
学科分类号
摘要
The natural refrigerants and hydrofluoroolefins (HFOs), which are proposed as alternatives to traditional refrigerants, have weaknesses in terms of flammability, cost, or system performance. As a solution, refrigerant mixtures offer the advantage of variable thermodynamic properties, but their main drawback is the composition change caused by the refrigerant leakage. This study analyzes the performance change during the leakage process, considering the combined effect of refrigerant amount reduction and composition shift. A mixture of R32/R1234yf with an initial composition of 20/80 wt% was utilized as a working fluid, and four leakage scenarios were employed: a vapor or liquid leak occurring during winter at -10 degrees C or summer at 30 degrees C. The composition change during the leakage was calculated by the simulation model, and then experiments were conducted to measure the performance with the calculated composition. The simulation results show that the vapor leak in winter leads to the most significant composition change of 7.8%p, when 57.1% of the initial charge escapes from the system. From the experimental results, the coefficient of performance (COP) exhibits the lowest value after the liquid leak in summer due to the increased mass fraction of R32, with a decrease of 89.5% compared to the initial COP. This degradation consists of 80.2%p due to refrigerant amount reduction and 9.3%p due to the composition shift. By considering the effects of both refrigerant amount and composition, this study provides a comprehensive analysis of the performance changes in a heat pump system during refrigerant mixture leakage.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Experimental study on the performance of a heat pump system with refrigerant mixtures' composition change
    Kim, M
    Kim, MS
    Kim, Y
    ENERGY, 2004, 29 (07) : 1053 - 1068
  • [2] Performance analysis of solar water heater combined with heat pump using refrigerant mixture
    Nuntaphan, Atipoang
    Chansena, Choosak
    Kiatsiriroat, Tanongkiat
    APPLIED ENERGY, 2009, 86 (05) : 748 - 756
  • [3] In situ measurement of circulation composition of refrigerant mixture in heat pump system with NIR absorption spectroscopy
    Miyawaki, Kosuke
    Ikeda, Soshi
    Hiratsuka, Kengo
    Shikazono, Naoki
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 150 : 1 - 8
  • [4] A Review on Flow Characteristics of Refrigerant and Oil Mixture in a Heat Pump System
    Kim, Hak Soo
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2015, 23 (03)
  • [5] Experimental study on the effect of refrigerant charging amount on the performance of CO2-air source heat pump system
    Liu, Zeqin
    Zhen, Huiran
    Chang, Yuan
    Han, Kaiyue
    Yu, Yongjie
    Yang, Yang
    Zhao, Taojie
    INTERNATIONAL CONFERENCE ON OPTOELECTRONIC MATERIALS AND DEVICES (ICOMD 2021), 2022, 12164
  • [6] The effect of the refrigerant charge amount on single and cascade cycle heat pump systems
    Kim, Dong Ho
    Park, Han Saem
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 40 : 254 - 268
  • [7] Effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump
    Cho, HY
    Ryu, CG
    Kim, YC
    Kim, HY
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08): : 1266 - 1273
  • [8] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    Li Kang
    Lan Jiao
    Zhou Guoliang
    Tang Qitian
    Cheng Qia
    Fang Yidong
    Su Lin
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (02) : 294 - 305
  • [9] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    Kang Li
    Jiao Lan
    Guoliang Zhou
    Qitian Tang
    Qia Cheng
    Yidong Fang
    Lin Su
    Journal of Thermal Science, 2019, 28 : 294 - 305
  • [10] Investigation on the Influence of Refrigerant Charge Amount on the Cooling Performance of Air Conditioning Heat Pump System for Electric Vehicles
    LI Kang
    LAN Jiao
    ZHOU Guoliang
    TANG Qitian
    CHENG Qia
    FANG Yidong
    SU Lin
    JournalofThermalScience, 2019, 28 (02) : 294 - 305