Fault Detection Algorithms in Medium-Voltage Direct-Current (MVDC) Grids

被引:1
作者
Blazquez, Aitor [1 ]
Perez-Molina, Maria Jose [2 ]
Larruskain, Dunixe Marene [1 ]
Iturregi, Araitz [1 ]
Eguia, Pablo [1 ]
机构
[1] Univ Basque Country UPV EHU, Dept Elect Engn, Plaza Ingn Torres Quevedo 1, Bilbao 48013, Spain
[2] Ocean Platform Canary Isl PLOCAN, Carretera Taliarte s-n Lighthouse, Telde 35214, Spain
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 23期
关键词
fault detection; fault diagnosis; power converters; power electronics; PROTECTION; MMC;
D O I
10.3390/app142311052
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Developing reliable protection systems is critical for the advancement of medium-voltage direct-current (MVDC) grids. This paper highlights the significance of fault detection in MVDC grids, especially in ensuring the reliability and efficiency of renewable energy systems. This paper provides a comparative analysis of fault detection algorithms, including overcurrent, undervoltage, rate of change of current (ROCOC), rate of change of voltage (ROCOV), differential, and inductor voltage derivative methods. The performance of these algorithms is quantified by metrics such as the detection speed, accuracy, and sensitivity under diverse scenarios. The authors assess these algorithms within a multi-terminal MVDC grid designed for renewable hydrogen production, evaluating the detection speed across various fault types (bus and link faults) and conditions, including the variation in the fault location and resistance. The results reveal that the UV, ROCOC, ROCOV and LIVRD methods achieve detection speeds as high as 0.01 ms, outperforming other techniques under low-resistance fault conditions. By using uniform fault scenarios, we identify the most effective algorithms for rapid fault detection, aiming to enhance the protection strategies for MVDC grids. These findings underline critical performance differences between methods, guiding the design of tailored protection schemes that address specific fault challenges in renewable-powered grids. Additionally, the practical implications of these findings for designing resilient protection schemes in renewable-powered grids are discussed. Simulations are conducted using PSCAD/EMTDC V4.6 software, ensuring the consistency and accuracy of the performance comparison. The insights gained provide a concrete understanding of each algorithm's trade-offs, enabling informed decisions when selecting optimal fault detection methods to ensure MVDC grid reliability.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Evaluating Phase Over-current Protection Philosophies for Medium-voltage Feeders Applying Let-through Energy and Voltage Dip Minimization
    Slabbert, Martin J.
    van Zyl, Stuart J.
    Naidoo, Raj
    Bansal, Ramesh C.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (02) : 206 - 218
  • [42] An Improved Method Using Artificial Neural Network for Fault Detection and Fault Pole Identification in Voltage Source Converter-Based High-Voltage Direct Current Transmission Lines
    Agarwal, Shobha
    Swetapadma, Aleena
    Panigrahi, Chinmoy
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2018, 43 (08) : 4005 - 4018
  • [43] Analysis of DC offset in fault current caused by machines in a medium voltage distribution network
    Bashar, Erfan
    Han, Qin
    Wu, Ruizhu
    Ran, Li
    Alatise, Olayiwola
    Jupe, Samuel
    [J]. JOURNAL OF ENGINEERING-JOE, 2019, (17): : 3494 - 3499
  • [44] An Improved Method Using Artificial Neural Network for Fault Detection and Fault Pole Identification in Voltage Source Converter-Based High-Voltage Direct Current Transmission Lines
    Shobha Agarwal
    Aleena Swetapadma
    Chinmoy Panigrahi
    [J]. Arabian Journal for Science and Engineering, 2018, 43 : 4005 - 4018
  • [45] Multiple criteria fault detection of BLDC (Brushless Direct Current) motor
    Maldonado Ruelas, Victor Arturo
    Villalobos Pina, Francisco Javier
    Alvarez Salas, Ricardo
    Morones Alba, Jose Alejandro
    Ortiz Medina, Raril Arturo
    [J]. DYNA, 2018, 93 (05): : 556 - 562
  • [46] A Fault Detection Method for Photovoltaic Systems Based on Voltage and Current Observation and Evaluation
    Pei, Tingting
    Hao, Xiaohong
    [J]. ENERGIES, 2019, 12 (09)
  • [47] An integration fault detection method using stator voltage for marine current turbines
    Xie, Tao
    Li, Zhichao
    Wang, Tianzhen
    Shi, Ming
    Wang, Yide
    [J]. OCEAN ENGINEERING, 2021, 226
  • [48] Wavelet based Method for Fault Detection in Medium Voltage DC Shipboard Power Systems
    Li, Weilin
    Luo, Min
    Monti, Antonello
    Ponci, Ferdinanda
    [J]. 2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 2155 - 2160
  • [49] Long-Horizon Robust Direct Model Predictive Control for Medium-Voltage Induction Motor Drives With Reduced Computational Complexity
    Tregubov, Andrei
    Karamanakos, Petros
    Ortombina, Ludovico
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (02) : 1775 - 1787
  • [50] Detection of faulted phases in a medium-voltage main feeder using the cyber grid guard system with distributed ledger technology
    Hahn, Gary
    Piesciorovsky, Emilio C.
    Hink, Raymond Borges
    Werth, Aaron
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 161