Research on calibration of radiance detector based on trap detector

被引:0
作者
Zou, Peng [1 ]
Zheng, Xiaobing [1 ]
Wu, Haoyu [1 ]
Li, Jianjun [1 ]
Liu, Enchao [1 ]
Hong, Jin [1 ]
Xiong, Wei [1 ]
机构
[1] Key Laboratory of Optics Calibration and Characterization, Chinese Academy of Sciences, Hefei
来源
Guangxue Xuebao/Acta Optica Sinica | 2013年 / 33卷 / 07期
关键词
Calibration; Cryogenic radiometer; Measurement; Radiance; Trap detector;
D O I
10.3788/AOS201333.0712002
中图分类号
学科分类号
摘要
Radiance detector (RD) is composed of trap detector, interference filter and precision stops. Its radiance responsivity can be traced from the cryogenic absolute radiometer. The absolute spectral responsivity of RD is obtained by measuring absolute responsivity of trap detector, spectral transmittance of filter, gain of trans-impedance amplifier, diameters of field stop and aperture stop and the distance between them, accurately. The overall performance is measured and the uncertainties are evaluated in detail. The combined standard uncertainty in the absolute spectral radiance responsivity calibration is less than 1.26% (confidence probability coefficient k=1), which can meet the high-precision calibration requirement of remote sensors.
引用
收藏
相关论文
共 16 条
[1]  
Martin J.E., Fox N.P., Key P.J., A cryogenic radiometer for absolute radiometric measurements, Metrologia, 21, 3, pp. 147-155, (1985)
[2]  
Fox N.P., Trap detectors and their properties, Metrologia, 28, 3, pp. 197-202, (1991)
[3]  
Johnson B.C., Cromer C.L., Saunders R.D., Et al., A method of realizing spectral irradiance based on an absolute cryogenic radiometer, Metrologia, 30, 4, pp. 309-315, (1993)
[4]  
Johnson B.C., Brown S.W., Eppeldauer G.P., Et al., System-level calibration of a transfer radiometer used to validate EOS radiance scales, International Journal of Remote Sensing, 24, 2, pp. 339-356, (2003)
[5]  
Ahtee V., Brown S.W., Larason T.C., Et al., Comparison of absolute spectral irradiance responsivity measurement techniques using wavelength-tunable lasers, Appl Opt, 46, 20, pp. 4228-4236, (2007)
[6]  
Liu Y.J., Xu G., Ojanen M., Et al., Spectral irradiance comparison using a multi-wavelength filter radiometer, Metrologia, 46, S1, pp. 81-85, (2009)
[7]  
Brown S.W., Saunders R.D., Li Z., Et al., An absolute detector-based spectral radiance source, SPIE, 7807, (2010)
[8]  
Yang X., Wang S., Huang Y., Et al., Wavelength dependence of the spectral irradiance of standard lamp and bi-reflection distribution function of diffuser based on standard detectors, Acta Optica Sinica, 31, 6, (2011)
[9]  
Zhang C., Xiang Y., Accuracy analysis of imaging spectrometer radiometric calibration using standard detector-diffuser method, Laser & Optoelectronics Progress, 48, 6, (2011)
[10]  
Johnson B.C., Fowler J.B., Cromer C.L., SeaWiFS Postlaunch Technical Report Series, The SeaWiFS Transfer Radiometer, 1, (1998)