Determination of Sennoside A in Rat Plasma by Liquid Chromatography/Electrospray Ionization Tandem Mass Spectrometry and Its Application to a Rat Pharmacokinetic Study

被引:1
|
作者
Sun, Jingjing [1 ]
Gu, Yifan [2 ]
Gu, Chunyan [2 ]
Qi, Wen [2 ]
Chu, Feifei [2 ]
Shen, Jiawei [2 ]
机构
[1] Wujing Community Hlth Serv Ctr, Dept Gen Med, Shanghai, Peoples R China
[2] Shanghai Minhang Hosp Integrated Tradit Chinese &, Dept Pharmacol, Shanghai, Peoples R China
关键词
LC-MS/MS; method validation; pharmacokinetic; sennoside A;
D O I
10.1002/bmc.6049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To characterize pharmacokinetic profile of sennoside A in rats after intravenous and oral administration, a simple and sensitive liquid chromatography tandem mass spectrometry method was established and validated for quantitative determination of sennoside A in rat plasma. After prepared by protein precipitation with acetonitrile, sennoside A and internal standard were separated on a Waters ACQUITY HSS T3 (2.1 x 100 mm, 1.8 mu m) column using acetonitrile and 5-mM ammonium acetate in water as mobile phase by gradient elution. The method showed excellent linearity over the range of 0.5-1000 ng/mL with acceptable intra- and inter-day precision, accuracy, matrix effect, and recovery. The stability assay indicated that sennoside A was stable in plasma during the sample collection, preparation, and analysis. Next, the method was applied to pharmacokinetic study of sennoside A in rats. After intravenous and intragastric administrated to rats, the concentrations of sennoside A in plasma at different time points were quantitated and the pharmacokinetic parameters were calculated by software of DAS 2.0. Pharmacokinetic parameters suggested that after oral administration, sennoside A was reached to the peak at 2.9-3.6 h with a Cmax value of 13.2-31.7 ng/mL. Sennoside A was eliminated slowly from the plasma with T1/2 value between 15.4 and 18.3 h. The oral absolute bioavailability was among 0.9%-1.3%, which indicated low blood exposure level.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Quantitation of catalpol in rat plasma by liquid chromatography/electrospray ionization tandem mass spectrometry and its pharmacokinetic study
    Lu, Rong
    Gu, Yuan
    Si, Duanyun
    Liu, Changxiao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3589 - 3594
  • [2] Determination of chrysotoxine in rat plasma by liquid chromatography-tandem mass spectrometry and its application to a rat pharmacokinetic study
    Fan, Jingjing
    Guan, Li
    Kou, Zeqi
    Feng, Feng
    Zhang, Yanbo
    Liu, Wenyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 57 - 62
  • [3] Determination of chamaechromone in rat plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Lou, Yan
    Hu, Haihong
    Liu, Yao
    Yu, Qinqin
    Li, Li
    Ping, Li
    Yu, Lushan
    Jiang, Huidi
    Zeng, Su
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1163 - 1169
  • [4] A Validated Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Methylophiopogonanone A in Rat Plasma and Its Application to Pharmacokinetic Study
    Xie, Tiantian
    Hao, Yanling
    Xie, Yanzheng
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (01)
  • [5] Determination of larotaxel and its metabolites in rat plasma by liquid chromatography-tandem mass spectrometry: Application for a pharmacokinetic study
    Liu, Zhenzhen
    Zhang, Lunhui
    Ju, Ping
    Hou, Pengyi
    Zhang, Yuanyuan
    Tang, Xing
    Bi, Kaishun
    Chen, Xiaohui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 132 - 138
  • [6] Development of a liquid chromatography/tandem mass spectrometry assay for the determination of bestatin in rat plasma and its application to a pharmacokinetic study
    Wang, Chen
    Fan, Guorong
    Lin, Mei
    Chen, Yi
    Zhao, Weiquan
    Wu, Yutian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 101 - 108
  • [7] Determination of Tenacissoside A in rat plasma by liquid chromatography-tandem mass spectrometry method and its application to pharmacokinetic study
    Zhao, Luhua
    Xiang, Bingren
    Chen, Jing
    Tan, Xiying
    Wang, Dawei
    Chen, Daofeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1799 - 1804
  • [8] Quantification of thonningianin a in rat plasma by liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study
    Liu, Qian
    Li, Chunmin
    Zhao, Pan
    Li, Jing
    Deng, Zhipeng
    PHARMACEUTICAL BIOLOGY, 2021, 59 (01) : 525 - 531
  • [9] Determination of penciclovir in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study
    Kanneti, Ravi
    Bhavesh, Dasandi
    Paramar, Dharmesh
    Shivaprakash, R.
    Bhatt, Parloop A.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (04) : 458 - 465
  • [10] Determination of lovastatin in human plasma by ultra-performance liquid chromatography - electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study
    Yuan, Haiyan
    Wang, Feng
    Tu, Jiying
    Peng, Wenxing
    Li, Huande
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) : 808 - 813