Pollution measurement technology of insulators for UHVDC

被引:0
|
作者
Cao, Yanming [1 ]
Ma, Weimin [1 ]
机构
[1] Beijing Wanglian HVDC Engineering Technology Co., Ltd., Beijing 100005, China
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In recent years, HVDC transmission project is developing greatly in China and the ±800 kV UHVDC project prepares for construction in the future. This paper introduce the oversea and domestic research situation of pollution performance and withstand voltage at pollution condition for insulators used under ultra voltage direct current (UHVDC). The design method of environment pollution station and insulators experimented in the station are recommended with the requirement of UHVDC project. Several pollution experiment methods used in domestic and overseas for DC pollution has been analysed and compared so as to summarize a new principle which DC and AC special insulators for contrasting experiment in the article. Via gathering the surface dirt accumulated at insulators, several viable pollution measurements such as measure salt deposit density (ESSD) and dust deposit is put forward on the basement of experiment data collected by the station operating. In the experiments, the problem that how to measure the pollution rate of direct current and alternating current are also discussed. Considering the experiment error, a corrected measure that setting a DC insulator without electricity to accumulated dirt for contrasting the insulators with electricity is designed. At last, the usage of the DC and AC pollution rate under UHVDC is preliminarily researched in the paper.
引用
收藏
页码:22 / 25
相关论文
共 50 条
  • [21] Suppression Method for Electrolytic Corrosion of Porcelain Insulators' Iron Caps on UHVDC Transmission Lines
    Luo, Ling
    Wang, Liming
    Guan, Zhicheng
    Mei, Hongwei
    Li, Licheng
    Zhang, Fuzeng
    Liao, Yifan
    Li, Ruihai
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2448 - 2457
  • [22] Applying the right technology to the right application in air pollution measurement
    Anon
    Foundryman, 1994, 87 (pt 7): : 243 - 245
  • [23] Fast measurements - use of biosensor technology for measurement of environmental pollution
    Lehmann, M.
    Riedel, K.
    Adler, K.
    Kunze, G.
    Chemie-Technik (Heidelberg), 1998, 27 (06): : 104 - 105
  • [24] Implementation of New Computer Technology for UHVDC Power of Transmission
    Yuan, Q. Y.
    2008 IEEE REGION 8 INTERNATIONAL CONFERENCE ON COMPUTATIONAL TECHNOLOGIES IN ELECTRICAL AND ELECTRONICS ENGINEERING: SIBIRCON 2008, PROCEEDINGS, 2008, : 114 - 117
  • [25] Pollution Performance of HVDC SiR Insulators at Extra Heavy Pollution Conditions
    Abbasi, A.
    Shayegani, A.
    Niayesh, K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (02) : 721 - 728
  • [26] A Novel Method for Visualizing the Pollution Distribution of Insulators
    Yin, Chengfeng
    Guo, Yujun
    Zhang, Xueqin
    Huang, Guizao
    Wu, Guangning
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [27] Flashover of discontinuous pollution layer on HV insulators
    Ecole Nationale Polytechnique d'Alger, Alger, Algeria
    不详
    IEEE Trans Dielectr Electr Insul, 6 (900-906):
  • [28] FLASHOVERS OF INSULATORS UNDER NATURAL POLLUTION AND HVDC
    HIRSCH, F
    RHEINBABEN, HV
    SORMS, R
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (01): : 45 - 50
  • [29] Flashover of discontinuous pollution layer on HV insulators
    Mekhaldi, A
    Namane, D
    Bouazabia, S
    Beroual, A
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (06) : 900 - 906
  • [30] Pollution accumulation on silicone rubber and on porcelain insulators