Simulative calculation of 10 kV network single-phase grounding overvoltage

被引:0
|
作者
Xia, Xiaofei [1 ]
Xu, Fei [1 ]
机构
[1] Guangxi Power Test and Research Institute, Nanning 530023, China
关键词
Capacitance - Electric power distribution - Electric grounding;
D O I
暂无
中图分类号
学科分类号
摘要
The various factors causing overvoltage are theoretically researched with ATP(Alternative Transient Program) and the simulation model is established according to the data of a real substation. Several factors causing distribution network overvoltage are simulated: arc occurrence instant, arc resistance, fault distance, system-to-ground capacitance. Results show that their influences on single-phase grounding overvoltage are different: the arc occurrence instant has the greatest influence and the arc resistance has less influence, while the fault distance and system-to-ground capacitance have the least influence.
引用
收藏
页码:75 / 76
相关论文
共 50 条
  • [1] Single-phase grounding overvoltage of long-distance UHVAC lines
    Li, Yang
    Shen, Yang
    Zhou, Hao
    Ji, Rongrong
    Sun, Ke
    Ding, Jian
    Qian, Feng
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (12): : 98 - 104
  • [2] A new method of single-phase grounding fault protection for a resonant grounding distribution network based on unbalanced overvoltage dynamic suppression
    Liu Z.
    Zeng X.
    Yu K.
    Liu S.
    Li L.
    Xu P.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (08): : 41 - 49
  • [3] Analysis of Disturbance to Secondary Cable Caused by Single-phase Grounding Fault in Typical 10kV Distribution network
    Xiao, Fengnyu
    He, Ziming
    Liu, Zhuoran
    IET Conference Proceedings, 2022, 2022 (05): : 194 - 200
  • [4] Dynamics Simulation of 10 kV Cable Tunnel Fire for Single-phase Arc Grounding Fault
    Liu S.
    Hu Y.
    Zheng J.
    Su X.
    Xu Y.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (12): : 4341 - 4348
  • [5] Influence of the arc suppression coil with parallel resistance on single-phase arc grounding overvoltage
    Xue, Han
    Song, JiJiang
    Cui, YuChong
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ELECTRICAL ENGINEERING, 2013, 676 : 284 - 288
  • [6] The Analysis of Overvoltage on 220kV Transmission Line in Single-phase Reclosing
    Cheng, Qiang
    Wang, Dong-qing
    Fan, Li-qin
    Liu, Xin-yuan
    2016 INTERNATIONAL CONFERENCE ON POWER, ENERGY ENGINEERING AND MANAGEMENT (PEEM 2016), 2016, : 25 - 31
  • [7] Automatic Processing of Single-phase Grounding Fault in Distribution Network Based on Fault Phase Grounding
    Liu J.
    Zhang Z.
    Li Y.
    Rui J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (12): : 169 - 177
  • [8] Simulative Study for the Impact of Signal Frequency on Precision of Grounding Wire Detection in 10kV Distribution Network
    Lu, Jun
    Cheng, Lefeng
    Yu, Tao
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY AND ENVIRONMENTAL SCIENCE 2015, 2015, 31 : 1269 - 1273
  • [9] Calculation of single-phase short-circuit current in compound protective grounding
    Zabusov, V.V.
    Averbukh, M.A.
    Pankrushina, I.V.
    Dotsenko, N.V.
    Promyshlennaya Energetika, 2002, (11): : 41 - 44