Design and implementation of LCL-filter-based grid-connected inverters without damping

被引:0
|
作者
机构
[1] Jiangsu Provincial Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics and Astronautics
[2] School of Electrical Engineering, Yancheng Institute of Technology
来源
Yao, Z. (nhyzl@163.com) | 2013年 / Science Press卷 / 39期
关键词
Digital control; Grid-connected; Inverters; LCL filter; Stability; Undamped;
D O I
10.3969/j.issn.1003-6520.2013.05.031
中图分类号
学科分类号
摘要
Suppressing resonances of LCL filter by either passive or active damping would increase loss or cost of a system. Therefore, we proposed a design method for numerical-controlled, undamped, LCL-filter-based, and space-vector-pulse-width-modulating (SVPWM) grid-connected inverters, which could realize stable system operation with appropriate design of parameters. A z-domain model of the grid-connected inverter was established, and the design procedure and an example of the system were provided in detail. Finally, experiments of a 15 kVA prototype of the proposed inverter were carried out. The results prove that the designed grid-connected inverter is a stable system, which keeps operating stably even under a sudden load change. Compared with active damping methods, the proposed grid-connected inverter does not need current sensor or voltage sensor, which might reasonably reduce the system cost. Besides, compared with passive damping methods, the proposed inverter has higher efficiency and smaller total harmonic distortion (THD) of grid current.
引用
收藏
页码:1232 / 1237
页数:5
相关论文
共 23 条
  • [1] Sun P., Liu C., Lai J.S., Et al., Grid-tie control of cascade dual-buck inverter with wide-range power flow capability for renewable energy applications, IEEE Transactions on Power Electronics, 27, 4, pp. 1839-1849, (2012)
  • [2] Huang L., Ma Y., Sun K., Et al., Control of high efficiency cascaded photovoltaic grid-connected inverter, High Voltage Engineering, 37, 3, pp. 680-686, (2011)
  • [3] Dai X., Chao Q., Research of adaptive current hysteresis band track control for photovoltaic grid-connected inverter, Power System Protection and Control, 38, 4, pp. 25-30, (2010)
  • [4] Wai R.J., Jhung S.J., Liaw J.J., Et al., Intelligent optimal energy management system for hybrid power sources including fuel cell and battery, IEEE Transactions on Power Electronics, 28, 7, pp. 3231-3244, (2013)
  • [5] Zhang Z., Hu Z., Li Y., Design of wide-area damping controller of grid-tied wind generation system based DFIG, High Voltage Engineering, 37, 1, pp. 157-163, (2011)
  • [6] Zeng Z., Yang H., Zhao R., Robust control strategy for grid-connected inverters with LCL filter, High Voltage Engineering, 37, 12, pp. 3143-3150, (2011)
  • [7] Li R., Ma Z., Xu D., Et al., A high efficiency soft switching three-phase grid-connected inverter, Automation of Electric Power Systems, 35, 3, pp. 62-66, (2011)
  • [8] Yang S., Zhang X., Zhang C., Et al., Strategy design of multiple feedback loop control for grid-connected voltage source inverter with LCL filter, Automation of Electric Power Systems, 35, 5, pp. 66-70, (2011)
  • [9] Yao Z., Xiao L., He L., Et al., A control strategy for grid-interactive inverters with rectifier loads, Automation of Electric Power Systems, 34, 22, pp. 80-84, (2010)
  • [10] Jeong H.G., Lee K.B., Choi S., Et al., Performance improvement of LCL-filter-based grid-connected inverters using PQR power transformation, IEEE Transactions on Power Electronics, 25, 5, pp. 1320-1330, (2010)