A novel proposition of radiation energy conservation in radiation dose deformation using deformable image registration

被引:0
|
作者
Kim, Jihun [1 ]
Yoon, Kyungho [2 ]
Kim, Jun Won [1 ]
Kim, Jin Sung [3 ,4 ]
机构
[1] Yonsei Univ, Gangnam Severance Hosp, Dept Radiat Oncol, Coll Med, Seoul, South Korea
[2] Yonsei Univ, Sch Math & Comp Computat Sci & Engn, Seoul, South Korea
[3] Yonsei Univ, Heavy Ion Therapy Res Inst, Yonsei Canc Ctr, Dept Radiat Oncol,Coll Med, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 24期
基金
新加坡国家研究基金会;
关键词
radiation energy conservation; dose accumulation; deformable image registration; uncertainty quantification; energy difference error; MASS CHANGES; EXPERIMENTAL VALIDATION; ACCUMULATION; TUMORS;
D O I
10.1088/1361-6560/ad9542
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this study is to analytically derive and validate a novel radiation energy conservation principle for dose mapping via deformable image registration (DIR). Approach. A radiation energy conservation principle for the DIR-based dose-deforming process was theoretically derived with a consideration of the volumetric Jacobian and proven using synthetic examples and a patient case. Furthermore, an energy difference error was proposed that can be used to evaluate the DIR-based dose accumulation uncertainty. For the analytical validation of the proposed energy conservation principle, a synthetic isotropic deformation was considered, and artificial deformation uncertainties were introduced. For the validation with a patient case, a ground truth set of computed tomography images and the corresponding deformation was generated. Radiation energy calculation was performed using both the ground truth deformation and another deformation with uncertainty. Main results. The suggested energy conservation principle was preserved with uncertainty-free deformation, but not with error-containing deformations using both the synthetic examples and the patient case. For a synthetic example with a tumor volume reduction of 27.1% (10% reduction in length in all directions), the energy difference error was calculated to be -29.8% and 37.2% for an over-deforming and under-deforming DIR uncertainty of 0.3 cm. The energy difference error for the patient case (tumor volume reduction of 37.6%) was 2.9% for a displacement vector field with a registration error of 2.0 +/- 3.2 mm. Significance. A novel energy conservation principle for DIR-based dose deformation and the corresponding energy difference error were mathematically formulated and successfully validated using simple synthetic examples and a patient example. With a consideration of the volumetric Jacobian, this investigation proposed a radiation energy conservation principle which can be met only with uncertainty-free deformations.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Local statistical deformation models for deformable image registration
    Tang, Songyuan
    Cong, Weijian
    Yang, Jian
    Fu, Tianyu
    Song, Hong
    Ai, Danni
    Wang, Yongtian
    NEUROCOMPUTING, 2018, 303 : 1 - 10
  • [42] Quantitative Evaluation of Deformable Image Registration in MRI- Guided Adaptive Radiation Therapy
    Mooney, K.
    Zhao, T.
    Duan, Y.
    Zhang, M.
    Green, O.
    Mutic, S.
    Yang, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3737 - 3737
  • [43] Establishment of Benchmark CBCT/CT Deformable Image Registration in Radiation Therapy of Prostate Cancer
    Kumar, S.
    Siddiqui, S. U.
    Yechieli, R.
    Shah, M.
    Robbins, J.
    El Saka, R.
    Elshaikh, M.
    Pradhan, D.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S814 - S814
  • [44] Assessment of Accuracy and Reproducibility of Automatic Deformable Image Registration for Head and Neck Radiation Therapy
    Speight, R.
    Perkinson, A.
    Lindsay, R.
    Artschan, R.
    Prestwich, R.
    Sykes, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S732 - S733
  • [45] An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy
    Liao, Yuliang
    Wang, Linjing
    Xu, Xiangdong
    Chen, Haibin
    Chen, Jiawei
    Zhang, Guoqian
    Lei, Huaiyu
    Wang, Ruihao
    Zhang, Shuxu
    Gu, Xuejun
    Zhen, Xin
    Zhou, Linghong
    MEDICAL PHYSICS, 2017, 44 (06) : 2369 - 2378
  • [46] Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy
    Lu, Weiguo
    Olivera, Gustavo H.
    Chen, Quan
    Ruchala, Kenneth J.
    Haimerl, Jason
    Meeks, Sanford L.
    Langen, Katja M.
    Kupelian, Patrick A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17): : 4357 - 4374
  • [47] Region-based Correction of Deformable Image Registration Errors for Adaptive Radiation Therapy
    Zhong, H.
    Li, S.
    Wen, N.
    Chetty, I.
    Movsas, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S797 - S797
  • [48] Evaluation of Biomechanical Deformable Image Registration (DIR) in a Commercial Radiation Therapy Planning System
    Velec, M.
    Moseley, J. L.
    Svensson, S.
    Craig, T.
    Menard, C.
    Hardemark, B.
    Brock, K. K.
    Jaffray, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S215 - S216
  • [49] Assessment of a model-based deformable image registration approach for radiation therapy planning
    Kaus, Michael R.
    Brock, Kristy K.
    Pekar, Vladimir
    Dawson, Laura A.
    Nichol, Alan M.
    Jaffray, David A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02): : 572 - 580
  • [50] Patient-specific validation of deformable image registration in radiation therapy: Overview and caveats
    Paganelli, Chiara
    Meschini, Giorgia
    Molinelli, Silvia
    Riboldi, Marco
    Baroni, Guido
    MEDICAL PHYSICS, 2018, 45 (10) : E908 - E922