A novel proposition of radiation energy conservation in radiation dose deformation using deformable image registration

被引:0
|
作者
Kim, Jihun [1 ]
Yoon, Kyungho [2 ]
Kim, Jun Won [1 ]
Kim, Jin Sung [3 ,4 ]
机构
[1] Yonsei Univ, Gangnam Severance Hosp, Dept Radiat Oncol, Coll Med, Seoul, South Korea
[2] Yonsei Univ, Sch Math & Comp Computat Sci & Engn, Seoul, South Korea
[3] Yonsei Univ, Heavy Ion Therapy Res Inst, Yonsei Canc Ctr, Dept Radiat Oncol,Coll Med, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 24期
基金
新加坡国家研究基金会;
关键词
radiation energy conservation; dose accumulation; deformable image registration; uncertainty quantification; energy difference error; MASS CHANGES; EXPERIMENTAL VALIDATION; ACCUMULATION; TUMORS;
D O I
10.1088/1361-6560/ad9542
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this study is to analytically derive and validate a novel radiation energy conservation principle for dose mapping via deformable image registration (DIR). Approach. A radiation energy conservation principle for the DIR-based dose-deforming process was theoretically derived with a consideration of the volumetric Jacobian and proven using synthetic examples and a patient case. Furthermore, an energy difference error was proposed that can be used to evaluate the DIR-based dose accumulation uncertainty. For the analytical validation of the proposed energy conservation principle, a synthetic isotropic deformation was considered, and artificial deformation uncertainties were introduced. For the validation with a patient case, a ground truth set of computed tomography images and the corresponding deformation was generated. Radiation energy calculation was performed using both the ground truth deformation and another deformation with uncertainty. Main results. The suggested energy conservation principle was preserved with uncertainty-free deformation, but not with error-containing deformations using both the synthetic examples and the patient case. For a synthetic example with a tumor volume reduction of 27.1% (10% reduction in length in all directions), the energy difference error was calculated to be -29.8% and 37.2% for an over-deforming and under-deforming DIR uncertainty of 0.3 cm. The energy difference error for the patient case (tumor volume reduction of 37.6%) was 2.9% for a displacement vector field with a registration error of 2.0 +/- 3.2 mm. Significance. A novel energy conservation principle for DIR-based dose deformation and the corresponding energy difference error were mathematically formulated and successfully validated using simple synthetic examples and a patient example. With a consideration of the volumetric Jacobian, this investigation proposed a radiation energy conservation principle which can be met only with uncertainty-free deformations.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Usefulness of hybrid deformable image registration algorithms in prostate radiation therapy
    Motegi, Kana
    Tachibana, Hidenobu
    Motegi, Atsushi
    Hotta, Kenji
    Baba, Hiromi
    Akimoto, Tetsuo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 229 - 236
  • [22] FEM-based evaluation of deformable image registration for radiation therapy
    Zhong, Hualiang
    Peters, Terry
    Siebers, Jeffrey V.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16): : 4721 - 4738
  • [23] Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy
    Wang, H
    Dong, L
    O'Daniel, J
    Mohan, R
    Garden, AS
    Ang, KK
    Kuban, DA
    Bonnen, M
    Chang, JY
    Cheung, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (12): : 2887 - 2905
  • [24] Deformable image registration for radiation therapy: principle, methods, applications and evaluation
    Rigaud, Bastien
    Simon, Antoine
    Castelli, Joel
    Lafond, Caroline
    Acosta, Oscar
    Haigron, Pascal
    Cazoulat, Guillaume
    de Crevoisier, Renaud
    ACTA ONCOLOGICA, 2019, : 1225 - 1237
  • [25] Deformable Registration Using Edge Preserving Scale Space for Adaptive Image Guided Radiation Therapy
    Chen, J.
    Li, D.
    MEDICAL PHYSICS, 2011, 38 (06) : 3420 - +
  • [26] Improving Deformable Image Registration Accuracy using a Hybrid Similarity Metric for Adaptive Radiation Therapy
    Shah, Keyur
    Shackleford, James A.
    Kandasamy, Nagarajan
    Sharp, Gregory C.
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [27] A Novel Intensity Similarity Metric with Soft Spatial Constraint for a Deformable Image Registration Problem in Radiation Therapy
    Khamene, Ali
    Zikic, Darko
    Diallo, Mamadou
    Boettger, Thomas
    Rietzel, Eike
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 828 - +
  • [28] Radiation dose response simulation for biomechanical-based deformable image registration of head and neck cancer treatment
    Al-Mayah, Adil
    Moseley, Joanne
    Hunter, Shannon
    Brock, Kristy
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8481 - 8489
  • [29] Target and organ dose estimation from intensity modulated head and neck radiation therapy using 3 deformable image registration algorithms
    Kumarasiri, Akila
    Liu, Chang
    Siddiqui, Farzan
    Zhong, Hualiang
    Chetty, Indrin J.
    Kim, Jinkoo
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (04) : E317 - E325
  • [30] Deformable image registration and interobserver variation in contour propagation for radiation therapy planning
    Riegel, Adam C.
    Antone, Jeffrey G.
    Zhang, Honglai
    Jain, Prachi
    Raince, Jagdeep
    Rea, Anthony
    Bergamo, Angelo M.
    Kapur, Ajay
    Potters, Louis