A novel proposition of radiation energy conservation in radiation dose deformation using deformable image registration

被引:0
|
作者
Kim, Jihun [1 ]
Yoon, Kyungho [2 ]
Kim, Jun Won [1 ]
Kim, Jin Sung [3 ,4 ]
机构
[1] Yonsei Univ, Gangnam Severance Hosp, Dept Radiat Oncol, Coll Med, Seoul, South Korea
[2] Yonsei Univ, Sch Math & Comp Computat Sci & Engn, Seoul, South Korea
[3] Yonsei Univ, Heavy Ion Therapy Res Inst, Yonsei Canc Ctr, Dept Radiat Oncol,Coll Med, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 24期
基金
新加坡国家研究基金会;
关键词
radiation energy conservation; dose accumulation; deformable image registration; uncertainty quantification; energy difference error; MASS CHANGES; EXPERIMENTAL VALIDATION; ACCUMULATION; TUMORS;
D O I
10.1088/1361-6560/ad9542
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this study is to analytically derive and validate a novel radiation energy conservation principle for dose mapping via deformable image registration (DIR). Approach. A radiation energy conservation principle for the DIR-based dose-deforming process was theoretically derived with a consideration of the volumetric Jacobian and proven using synthetic examples and a patient case. Furthermore, an energy difference error was proposed that can be used to evaluate the DIR-based dose accumulation uncertainty. For the analytical validation of the proposed energy conservation principle, a synthetic isotropic deformation was considered, and artificial deformation uncertainties were introduced. For the validation with a patient case, a ground truth set of computed tomography images and the corresponding deformation was generated. Radiation energy calculation was performed using both the ground truth deformation and another deformation with uncertainty. Main results. The suggested energy conservation principle was preserved with uncertainty-free deformation, but not with error-containing deformations using both the synthetic examples and the patient case. For a synthetic example with a tumor volume reduction of 27.1% (10% reduction in length in all directions), the energy difference error was calculated to be -29.8% and 37.2% for an over-deforming and under-deforming DIR uncertainty of 0.3 cm. The energy difference error for the patient case (tumor volume reduction of 37.6%) was 2.9% for a displacement vector field with a registration error of 2.0 +/- 3.2 mm. Significance. A novel energy conservation principle for DIR-based dose deformation and the corresponding energy difference error were mathematically formulated and successfully validated using simple synthetic examples and a patient example. With a consideration of the volumetric Jacobian, this investigation proposed a radiation energy conservation principle which can be met only with uncertainty-free deformations.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Improving Dose Accuracy in Cancer Radiation Therapy Using Deformable Image Registration
    Amy Liu
    Yadin David
    Fred Hosea
    Richard Wu
    中国医疗设备, 2016, 31 (11) : 9 - 13+22
  • [2] Deformable image registration in radiation therapy
    Dowling, Jason A.
    O'Connor, Laura M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 257 - 259
  • [3] DEFORMABLE IMAGE REGISTRATION FOR RADIATION THERAPY
    Sarrut, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S47 - S47
  • [4] On Voxel-by-voxel Accumulated Dose for Prostate Radiation Therapy using Deformable Image Registration
    Yu, Jialu
    Hardcastle, Nicholas
    Jeong, Kyoungkeun
    Bender, Edward T.
    Ritter, Mark A.
    Tome, Wolfgang A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (01) : 37 - 47
  • [5] A Novel Metric to Evaluate Dose Deformation Error for Deformable Image Registration Algorithms
    Surucu, M.
    Roeske, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Accumulated Dose Estimation in Lung Stereotactic Body Radiation Therapy Using Deformable Image Registration Algorithm
    Wu, Q.
    Liu, C.
    Devpura, S.
    Ajlouni, M.
    Movsas, B.
    Chetty, I.
    MEDICAL PHYSICS, 2017, 44 (06) : 3222 - 3223
  • [7] Adaptive Radiation Therapy with Deformable Image Registration and 4D Dose Calculation
    Ali, I.
    Alsbou, N.
    Ahmad, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Implementing Radiation Dose-Volume Liver Response in Biomechanical Deformable Image Registration
    Polan, Daniel F.
    Feng, Mary
    Lawrence, Theodore S.
    Ten Haken, Randall K.
    Brock, Kristy K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (04): : 1004 - 1012
  • [9] Deformable registration for image-guided radiation therapy
    Sarrut, David
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 285 - 297
  • [10] Dose Deformation Error Associated with Deformable Image Registration Pathways
    Surucu, M.
    Woerner, A.
    Roeske, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3779 - 3779