Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria

被引:0
作者
Olaniyan T.A. [1 ]
Aborisade C.A. [1 ]
Balogun F.A. [2 ]
Ogunsina S.A. [1 ]
Saidu A. [3 ]
Ibrahim M.B. [1 ]
机构
[1] Department of Physics, Faculty of Sciences, Obafemi Awolowo University, Ile-Ife
[2] Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife
[3] Department of Physics, Faculty of Sciences, Usmanu Danfodiyo University, Sokoto
关键词
BEIR VII model; Computed tomography (CT); Eeffective dose; Radiation protection; Risk assessment;
D O I
10.22038/ijmp.2018.23516.1234
中图分类号
学科分类号
摘要
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on 160 patients undergoing eight most common types of CT examinations performed at the center, from December 5, 2015 to February 28, 2016. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (2006) report phase 2 models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was 5.88±3.75 mSv in a range of 0.78-19.00 mSv. The mean PSD was 0.274±0.229 mSv/kgm -2 in a range of 0.024-1.555 mSv/kgm -2 and the mean LAR of cancer incidence was 0.04861±0.03996 Sv -1 in a range of 0.00004-0.21942 Sv -1 . Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were 5.7%, 6.6%, 3.9%, 8.9%, 3.7%, 6.0%, 44.7%, and 19.2%, respectively. Accordingly, the coefficients of variation of PSD were 9.0%, 7.9%, 7.0%, 10.1%, 5.6%, 23.8%, 47.7%, and 14.2%. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:85 / 90
页数:5
相关论文
共 50 条
  • [21] Evaluating the impact of dose monitoring software alerts on radiation dose reduction in computed tomography: A systematic review
    Alanazi, Mohammed
    Kench, Peter
    Taba, Seyedamir
    Ekpo, Ernest
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [22] Cancer induction caused by radiation due to computed tomography: a critical note
    Pauwels, Ernest K. J.
    Bourguignon, Michel
    ACTA RADIOLOGICA, 2011, 52 (07) : 767 - 773
  • [23] Evaluation of the Comparative Effectiveness of Various Jurisdictional Computed Tomography Radiation Dose Reduction Models
    Li, A.
    Fan, M.
    Easty, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 787 - 790
  • [24] Technique and radiation dose of conventional X-rays and computed tomography of the sacroiliac joint
    Jurik A.G.
    Der Radiologe, 2004, 44 (3): : 229 - 233
  • [25] Technique and radiation dose of conventional X-rays and computed tomography of the sacroiliac joint
    Jurik, AG
    RADIOLOGE, 2004, 44 (03): : 229 - 233
  • [26] Patient dose evaluation in computed tomography: A French national study based on clinical indications
    Geryes, Bouchra Habib
    Hornbeck, Amaury
    Jarrige, Valerie
    Pierrat, Noelle
    Le Pointe, Hubert Ducou
    Dreuil, Serge
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 18 - 27
  • [27] Lung cancer screening Early diagnosis with low-dose computed tomography
    Ladage, D.
    Delorme, S.
    ONKOLOGE, 2022, 28 (01): : 40 - 48
  • [28] Lung cancer screening Early diagnosis with low-dose computed tomography
    Ladage, D.
    Delorme, S.
    ZEITSCHRIFT FUR PNEUMOLOGIE, 2023, 20 (05): : 244 - 257
  • [29] Lung cancer screening: Early diagnosis with low-dose computed tomography
    Ladage D.
    Delorme S.
    best practice onkologie, 2022, 17 (1-2) : 32 - 41
  • [30] Lung cancer screening Early diagnosis with low-dose computed tomography
    Ladage, D.
    Delorme, S.
    ZEITSCHRIFT FUR PNEUMOLOGIE, 2022, 19 (05): : 249 - 263