Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria

被引:0
作者
Olaniyan T.A. [1 ]
Aborisade C.A. [1 ]
Balogun F.A. [2 ]
Ogunsina S.A. [1 ]
Saidu A. [3 ]
Ibrahim M.B. [1 ]
机构
[1] Department of Physics, Faculty of Sciences, Obafemi Awolowo University, Ile-Ife
[2] Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife
[3] Department of Physics, Faculty of Sciences, Usmanu Danfodiyo University, Sokoto
关键词
BEIR VII model; Computed tomography (CT); Eeffective dose; Radiation protection; Risk assessment;
D O I
10.22038/ijmp.2018.23516.1234
中图分类号
学科分类号
摘要
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on 160 patients undergoing eight most common types of CT examinations performed at the center, from December 5, 2015 to February 28, 2016. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (2006) report phase 2 models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was 5.88±3.75 mSv in a range of 0.78-19.00 mSv. The mean PSD was 0.274±0.229 mSv/kgm -2 in a range of 0.024-1.555 mSv/kgm -2 and the mean LAR of cancer incidence was 0.04861±0.03996 Sv -1 in a range of 0.00004-0.21942 Sv -1 . Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were 5.7%, 6.6%, 3.9%, 8.9%, 3.7%, 6.0%, 44.7%, and 19.2%, respectively. Accordingly, the coefficients of variation of PSD were 9.0%, 7.9%, 7.0%, 10.1%, 5.6%, 23.8%, 47.7%, and 14.2%. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:85 / 90
页数:5
相关论文
共 50 条
  • [1] Rapid patient-specific organ dose estimation in computed tomography scans via integration of radiomics features and neural networks
    Shao, Wencheng
    Lin, Xin
    Huang, Ying
    Qu, Liangyong
    Zhuo, Weihai
    Liu, Haikuan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7379 - 7391
  • [2] A fast voxel-based Monte Carlo method for scanner- and patient-specific dose calculations in computed tomography
    Schmidt, B
    Kalender, WA
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2002, 18 (02): : 43 - 53
  • [3] Patient dose and image quality from the low kilovoltage dynamic liver computed tomography examinations
    Cho, Pyong-Kon
    Lee, Sung-Hyun
    Lee, Mi-Hwa
    Cho, Young-Kwon
    Chon, Kwon-Soo
    Kim, Yong-Min
    ASIAN BIOMEDICINE, 2013, 7 (01) : 119 - 124
  • [4] Patient radiation dose and protection from cone-beam computed tomography
    Li, Gang
    IMAGING SCIENCE IN DENTISTRY, 2013, 43 (02) : 63 - 69
  • [5] Development of acceptable quality radiation dose levels for common computed tomography examinations: A focused multicenter study in United Arab Emirates
    Elshami, Wiam
    Abuzaid, Mohamed
    Joseph, Dlama Z.
    Tekin, H. O.
    Ghonim, Hatem
    FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [6] Multidetector Computed Tomography Chest Examinations With Low-Kilovoltage Protocols in Adults: Effect on Image Quality and Radiation Dose
    Kim, Mi Jung
    Park, Chul Hi
    Choi, Soo Jin
    Hwang, Kyung Hoon
    Kim, Hyung Sik
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 416 - 421
  • [7] Radiation dose dependence on subject size in abdominal computed tomography: Water phantom and patient model comparison
    Li, Xinhua
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2018, 45 (05) : 2309 - 2317
  • [8] Radiation dose in multidetector row computed tomography cardiac imaging
    Bae, KT
    Hong, C
    Whiting, BR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 859 - 863
  • [9] Strategies of computed tomography radiation dose reduction: justification and optimization
    Do, Kyung-Hyun
    Sung, Dong-Wook
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2015, 58 (06): : 534 - 541
  • [10] Minimizing the Long-term Effects of Ionizing Radiation in Pediatric Computed Tomography Examinations
    Darnell, Kristina
    Morrison, Gary D.
    RADIOLOGIC TECHNOLOGY, 2016, 87 (05) : 495 - 501