Experimental analysis of live working on 750 kV compact double circuits transmission line on the same tower

被引:0
|
作者
Xiao, Bin [1 ]
Wang, Li-Nong [1 ]
Liu, Kai [1 ]
Liu, Ting [1 ]
Hu, Jian-Xun [1 ]
Cai, Jian-Feng [2 ]
Su, Zhan-Tao [3 ]
机构
[1] State Grid Electric Power Research Institute, Wuhan 430074, China
[2] Wuxi Electric Power Company, Wuxi 214000, China
[3] NARI Technology Development Company Limiled, Nanjing 210061, China
来源
关键词
Timing circuits - Occupational risks;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2863 / 2868
相关论文
共 50 条
  • [1] Experimental research of live working on 1000 kV double circuit AC transmission line on the same tower
    Hu, Yi
    Liu, Kai
    Wang, Li-Nong
    Shao, Gui-Wei
    Liu, Ting
    Hu, Jian-Xun
    Xiao, Bin
    Zheng, Chuan-Guang
    Xu, Ying
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (11): : 2668 - 2673
  • [2] Experimental research on live working carried on double circuit vertically arranged 500 kV compact transmission lines on the same tower
    Ding, Yujian
    Song, Gang
    Chen, Jiamiao
    Ying, Jianguo
    Xing, Yuelong
    Li, Qingfeng
    Liao, Weiming
    Dianwang Jishu/Power System Technology, 2013, 37 (11): : 3281 - 3287
  • [3] Research of live working on 750 kV double circuit AC transmission line
    Hu, Yi
    Wang, Li-Nong
    Liu, Kai
    Liu, Ting
    Hu, Jian-Xun
    Xiao, Bin
    Zheng, Chuan-Guang
    Xu, Ying
    Shao, Gui-Wei
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (02): : 373 - 378
  • [4] Experimental study on optimizing of grading rings in 750 kV compact two circuits transmission line
    School of Electric and Engineering, Wuhan University, Wuhan 430072, China
    不详
    不详
    Gaodianya Jishu, 2008, 11 (2390-2394):
  • [5] Comparative analysis on transposing modes for 750 kV compact double-circuit overhead transmission lines on same tower from Jinchang to Jiuquan
    China Electric Power Research Institute, Beijing 100192, China
    Dianli Xitong Zidonghue, 2009, 16 (102-107):
  • [6] Research on secondary-arc currents and induced voltages for 750 kV compact double-circuit transmission lines on the same tower with the same phase sequence in the same tower window
    Wang, Xiaotong
    Ban, Liangeng
    Zhu, Puxuan
    Zheng, Bin
    Dianwang Jishu/Power System Technology, 2011, 35 (01): : 84 - 90
  • [7] Analysis of failure trip rate of 1000 kV double circuits on the same tower
    State Grid Electric Power Research Institute, Wuhan 430074, China
    Gaodianya Jishu, 3 (441-444):
  • [8] Experimental Investigation on the minimum approach distance for Live Working on 1000kV UHV Compact Transmission Line
    Xiao, Bin
    Wu, Tian
    Liu, Kai
    Liu, Ting
    Peng, Yong
    Su, Ziming
    Tang, Pan
    Lei, Xinglie
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [9] Numerical analysis of potential distribution of porcelain insulator strings for 750 kV double-circuit transmission lines on the same tower
    Liu, Yu-Gen
    Tian, Jin-Hu
    Liu, Xiao-Wei
    Cheng, Xi
    Xiao, Lei-Shi
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1644 - 1650
  • [10] Experimental research on hot-line work of 750 kV single compact power transmission line
    Hebei Electric Power Research Institute, Shijiazhuang 050021, China
    不详
    不详
    Gaodianya Jishu, 2009, 11 (2876-2880):