Mathematical analysis of an ion chromatography determination for trace level perchlorate in drinking water

被引:0
作者
Lu, Ning [1 ]
Gao, Naiyun [1 ]
Chu, Wenhai [1 ]
机构
[1] State Key Laboratory of Pollution Control and Resources Reuse, Tongji University
来源
Tongji Daxue Xuebao/Journal of Tongji University | 2009年 / 37卷 / 09期
关键词
Cochran test; Detection limit; Ion chromatography; Perchlorate;
D O I
10.3969/j.issn.0253-374x.2009.09.012
中图分类号
学科分类号
摘要
Mathematical analysis of ICS1000+AS20 ion chromatography (IC) determination for trace level (2~50 μg·L-1) perchlorate (ClO4-) in water was investigated to optimize the instrument operating conditions and provide a lower detection limit. The Cochran test results reveal the homoscedasticity of the IC determination. The Lack of Fit (LOF) test results show that the operating conditions of AS16 column are not suitable for AS20. The recommended operating conditions of IC determination are 100 mA suppressor current, 35 mmol·L-1 eluent concentration, 1.0 mL·min-1 flow rate, and the standards are arranged in a random order. Method detection limit (MDL) yields a less reliable detection limit than detection limit from the calibration curve (DTC). The MDL of IC determination for trace level ClO4- is 0. 890 μg·L-1 and the DTC is 1.627 μg·L-1 under recommended operating conditions.
引用
收藏
页码:1203 / 1206+1231
相关论文
共 18 条
[1]  
Hurley K.D., Shapley J.R., Efficient heterogeneous catalytic reduction of perchlorate in water, Environmental Science and Technology, 41, 6, (2007)
[2]  
Charnley G., Perchlorate: Overview of risks and regulation, Food and Chemical Toxicology, 46, 7, (2008)
[3]  
Lu N., Gao N., Huang X., Adsorption of perchlorate in water by granular activated carbon and impact factors analysis, Environmental Science, 29, 6, (2008)
[4]  
Li X.A., Zhou D.M., Xu J.J., Et al., Determination of chloride, chlorate and perchlorate by PDMS microchip electrophoresis with indirect amperometric detection, Talanta, 75, 1, (2008)
[5]  
Huang H., Sorial G.A., Statistical evaluation of an analytical IC method for the determination of trace level perchlorate, Chemosphere, 64, 7, (2006)
[6]  
Kosaka K., Asami M., Matsuoka Y., Et al., Occurrence of perchlorate in drinking water sources of metropolitan area in Japan, Water Research, 41, 15, (2007)
[7]  
Johns C., Shellie R.A., Potter O.G., Et al., Identification of homemade inorganic explosives by ion chromatographic analysis of post-blast residues, Journal of Chromatography A, 1182, 2, (2008)
[8]  
Dette H., Marchlewski M., A test for the parametric form of the variance function in a partial linear regression model, Journal of Statistical Planning and Inference, 138, 10, (2008)
[9]  
Cacoullos T., The F-test of homoscedasticity for correlated normal variables, Statistics & Probability Letters, 54, 1, (2001)
[10]  
The specification for marine monitoring-Part 2:data processing and quality control of analysis