A novel DC current transformer (CT) based on the Faraday Effect has developed for DC railway power system. The advantages of the developed optical fiber CT are simple and light structure, easiness to handle and robustness to the external magnetic field caused by the adjacent electric current. The basic characteristics of the optical fiber CT are confirmed and compared with those of the conventional Hall CT and saturable reactor CT. Through the fired test and DC short circuit test, it is shown that the optical fiber CT realizes enough response and enough resolution for the practical application. Furthermore, its strong robustness to the external magnetic field is experimentally confirmed.
引用
收藏
页码:736 / 743+8
相关论文
共 50 条
  • [21] Calibration of Voltage and Current Transducers for DC Railway Systems
    Crotti, Gabriella
    Femine, Antonio Delle
    Gallo, Daniele
    Giordano, Domenico
    Landi, Carmine
    Luiso, Mario
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (10) : 3850 - 3860
  • [22] Power supply of electronic current transformer for power bus with low current
    Zhao, Qiangsong
    Ye, Yongqiang
    Xu, Guofeng
    Zhou, Xiaoyu
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (19): : 121 - 125
  • [23] DEVELOPMENT OF A FIBER OPTIC CURRENT SENSOR FOR POWER-SYSTEMS
    MACDOUGALL, TW
    LUTZ, DR
    WANDMACHER, RA
    IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (02) : 848 - 852
  • [24] DC method for measuring parameters of remanence of current transformer
    Chen, Gang, 1600, Science Press (40): : 2416 - 2421
  • [25] Analysis of influence of DC bias on instrument current transformer
    Tan, B. (tanbingyuan1988@126.com), 1600, Power System Technology Press (38): : 1408 - 1413
  • [26] Calculation of Errors in Current Transformer with DC Magnetic Bias
    Xie Qianxian
    Yang Jianming
    Hou Jing
    Song Hongtian
    Cai Yiqin
    Xu Chi
    2023 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA, I&CPS ASIA, 2023, : 1298 - 1303
  • [27] Development of Fault Point Locating System for Underground Transmission Lines Using Optical Fiber Current Sensors
    Kurosawa, Kiyoshi
    Kondo, Reishi
    Nasukawa, Shinsuke
    Yamaguchi, Tatsushi
    Amano, Kazuo
    ELECTRICAL ENGINEERING IN JAPAN, 2012, 178 (01) : 21 - 28
  • [28] Development of fault point locating system for underground transmission lines using optical fiber current sensors
    Kurosawa, Kiyoshi
    Kondo, Reishi
    Nasukawa, Shinsuke
    Yamaguchi, Tatsushi
    Amano, Kazuo
    IEEJ Transactions on Power and Energy, 2008, 128 (08) : 1035 - 1040+7
  • [29] Study on Long-term Operation Stability of Fiber Optical Current Transformer Based on Faraday Effect
    Wang, Hongxing
    Guan, Yuanpeng
    2015 INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORTATION, BIG DATA AND SMART CITY (ICITBS), 2016, : 767 - 770
  • [30] Optical fiber current sensor
    Simion, Viorica
    Pantelimon, Brandusa A.
    Stefanescu, Costin
    Faur, Daniela
    OPTIM 04: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL II: POWER ELECTRONICS, ELECTRICAL MACHINES AND DRIVES, 2004, : 283 - 286