Analysis of back-flashover lightning- withstanding level of 500-kv-double-circuit transmission lines

被引:0
|
作者
Wu, Shihong [1 ]
Wen, Xishan [1 ]
Li, Rui [1 ]
Xu, Yang [1 ]
机构
[1] College of Electrical Engineering, Wuhan University, Wuhan
来源
Lecture Notes in Electrical Engineering | 2015年 / 334卷
关键词
ATP-EMTP; Back-flashover; Double-circuit line; Lightning performance; Trip-out rate;
D O I
10.1007/978-3-319-13707-0_43
中图分类号
学科分类号
摘要
This chapter analyzes the lightning performance of 500-kV-double-circuit transmission lines by the Alternative Transient Performance-Electromagnetic Transient Program (ATP-EMTP). With towers using the multi-wave impedance model and eliminating voltage reflection on the lines by a matching resistor, a simulation method has been established to evaluate the factors that may influence the backflashover voltage such as tower height, tower footing resistance, and conductor phase arrangements. A statistical method is presented to calculate the line trip-out rates due to back-flashover. The results show that the impact of phase arrangements on the back-flashover trip-out rate of a single-circuit line is little, but significant on the double-circuit lines. © Springer International Publishing Switzerland 2015.
引用
收藏
页码:389 / 397
页数:8
相关论文
共 12 条
  • [1] Techniques for the improvement of the lightning back-flashover performance of double circuit HVDC lines
    Manduley, Nicolas
    Pack, Stephan
    Xemard, Alain
    Toure, Selle
    Raison, Bertrand
    Poullain, Serge
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 200
  • [2] Back-flashover resistance level of ±800 kV/500 kV AC-DC hybrid transmission lines
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu
    610031, China
    不详
    610000, China
    不详
    200122, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 10 (101-106 and 114): : 101 - 106and114
  • [3] Lightning back flashover double circuit tripping pattern of 132 kV lines in Malaysia
    Bakar, A. H. A.
    Talib, D. N. A.
    Mokhlis, H.
    Illias, H. A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 45 (01) : 235 - 241
  • [4] Flashover pattern analysis for 275 kV double circuit transmission lines during direct lightning strikes
    Ahmed, Nasiru Yahaya
    Illias, Hazlee Azil
    Mokhlis, Hazlie
    Fahmi, Daniar
    Abdullah, Noradlina
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
  • [5] Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines
    Lu, Hailiang
    Wen, Xishan
    Zhang, Chengwei
    Tong, Xuefang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3535 - +
  • [6] Research on Lightning Performance of Back-flashover of UHV Direct Current Double-circuit Mixed-voltage Transmission Lines on the Same Tower
    Li, Jinliang
    Ren, Huisong
    Xu, Li
    Long, Chenhai
    Yang, Qi
    Xiang, Yun
    2018 10TH INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS (ICCCAS 2018), 2018, : 50 - 54
  • [7] Numerical electromagnetic field analysis of archorn voltages during a back-flashover on a 500-kV twin-circuit line
    Mozumi, T
    Baba, Y
    Ishii, M
    Nagaoka, N
    Ametani, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (01) : 207 - 213
  • [8] Back Flashover Protection Performance Analysis of 220kV Double Circuit Transmission Line
    Wu Shuwen
    Sun Wenxin
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [9] Lightning Surge Analysis of HV Transmission Line: Bias AC-Voltage Effect on Multiphase Back-flashover
    Yamanaka, Akifumi
    Nagaoka, Naoto
    Baba, Yoshihiro
    2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [10] Lightning Surge Analysis of HV Transmission Line: Bias AC-Voltage Effect on Multiphase Back-Flashover
    Yamanaka, Akifumi
    Nagaoka, Naoto
    Baba, Yoshihiro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3570 - 3579