Pulsed electric field sensor based on original waveform measurement

被引:3
|
作者
Ma L. [1 ]
Wu W. [1 ]
Cheng Y. [1 ]
Zhou H. [1 ]
Li B. [1 ]
Li J. [1 ]
Zhu M. [1 ]
机构
[1] Northwest Institute of Nuclear Technology, Xi'an, 710024
关键词
High-altitude electromagnetic pulse; Measurement system; Original waveform measurement; Pulsed electric field;
D O I
10.3788/HPLPB20102211.2763
中图分类号
学科分类号
摘要
The paper introduces the differential and original waveform measurement principles for pulsed E-field, and develops an pulsed E-field sensor based on original waveform measurement along with its theor etical correction model. The sensor consists of antenna, integrator, amplifier and driver, optic-electric/electric-optic conversion module and transmission module. The time-domain calibration in TEM cell indicates that, its risetime response is shorter than 1.0 ns, and the output pulse width at 90% of the maximum amplitude is wider than 10.0 μs. The output amplitude of the sensor is linear to the electric field intensity in a dynamic range of 20 dB. The measurement capability can be extended to 10 V/m or 50 kV/m by changing the system's antenna and other relative modules.
引用
收藏
页码:2763 / 2768
页数:5
相关论文
共 8 条
  • [1] Description of HEMP environment radiated disturbance
  • [2] Li Y., Chen B., Shi L., Et al., Pulse electric field shielding effectiveness measurement system, High Power Laser and Particle Beams, 18, 6, pp. 972-976, (2006)
  • [3] Sheng Z., Electromagnetic Field and Microwave Technique and Antenna, (1995)
  • [4] Wu W., Zhou H., Ma L., Et al., The design method for the electric field probe based on Pspice, The Thirteenth Conference of Nuclear Electronics and Detection Technology, (2006)
  • [5] Xie Y., Jiao J., Zheng Z., Et al., Development and application of wide band electro optic measurement system for pulsed E-field, Nuclear Electronics and Detection Technology, 20, 1, pp. 43-46, (2000)
  • [6] Tong S., Fundamentals of Analog Electronic Technique, (2001)
  • [7] Yang Q., Fundamentals of Electronic Circuits, (1985)
  • [8] Chen W., He X., Jia W., Et al., Development of 2.5 MV fast rising pulse source for EMP simulator, The Fourteenth Conference of Nuclear Electronics and Detection Technology, (2008)