摘要
Proton exchange membrane (PEM) electrolysis is a promising technology for clean hydrogen production. To support safe deployments of PEM electrolyzers, we performed a failure modes and effects analysis (FMEA) on a lab-scale PEM electrolyzer to identify risk-significant scenarios. We identified 20 failure scenarios leading to a hydrogen release, 46 for an oxygen release, and 67 for hydrogen and oxygen mixing. Hydrogen fires or the collection of hydrogen and oxygen gas poses risk to facility personnel and surrounding equipment. The gas-water separators, pump supplying water to the electrolyzer stack, and electrolyzer stack were found to contribute to the most high-risk scenarios. Identifying these scenarios enables the mitigation of issues seen in early deployments and is a step toward a complete Quantitative Risk Assessment. The results provide a technical basis to support risk-informed safe and reliable deployment and operation of electrolyzer technologies by enabling development of safety plans, design, and operational strategies.
引用
收藏
页码:1280 / 1289
页数:10
相关论文
共 50 条
  • [1] Failure Modes and Effects Analysis (FMEA) for wind turbines
    Arabian-Hoseynabadi, H.
    Oraee, H.
    Tavner, P. J.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (07) : 817 - 824
  • [2] Failure Modes and Effects Analysis (FMEA) of the dispensing process
    Rogers, P.
    Hughes, D.
    PHARMACY WORLD & SCIENCE, 2008, 30 (04): : 386 - 387
  • [3] Failure Modes and Effects Analysis (FMEA) for Gamma Knife Radiosurgery
    Xu, Y.
    Bhatnagar, J.
    Bednarz, G.
    Flickinger, J.
    Arai, Y.
    Vacsulka, J.
    Feng, W.
    Monaco, E.
    Niranjan, A.
    Lunsford, L. Dade
    Huq, M. Saiful
    MEDICAL PHYSICS, 2015, 42 (06) : 3692 - 3693
  • [4] Failure modes and effects analysis (FMEA) for Gamma Knife radiosurgery
    Xu, Andy Yuanguang
    Bhatnagar, Jagdish
    Bednarz, Greg
    Flickinger, John
    Arai, Yoshio
    Vacsulka, Jonet
    Feng, Wenzheng
    Monaco, Edward
    Niranjan, Ajay
    Lunsford, L. Dade
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (06): : 152 - 168
  • [5] USING CAUSAL REASONING FOR AUTOMATED FAILURE MODES AND EFFECTS ANALYSIS (FMEA)
    BELL, D
    COX, L
    JACKSON, S
    SCHAEFER, P
    PROCEEDINGS ANNUAL RELIABILITY AND MAINTAINABILITY SYMPOSIUM, 1992, (SYM): : 343 - 353
  • [6] Failure Modes and Effects Analysis (FMEA) applied to two modern radiotherapy centres
    Teixeira, N
    Cunha, G
    Moreno, L
    Pontes, M
    Rosa, M
    Jacob, K
    Cardoso, I
    Ferreira, P
    Ramalho, M
    Carvoeiras, P
    Galhós, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S124 - S124
  • [7] Cost based Failure Modes and Effects Analysis (FMEA) for systems of accelerator magnets
    Spencer, CM
    Rhee, SJ
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2177 - 2179
  • [8] SYSTEMATIC MAINTENANCE AND APPLICATIONS OF FAILURE MODES AND EFFECTS ANALYSIS (FMEA) IN SEMICONDUCTOR MANUFACTURING
    Qian, Hongtao H. T.
    Liu, Ziqian Javaer
    Xu, Yuhong Betsy
    2017 CHINA SEMICONDUCTOR TECHNOLOGY INTERNATIONAL CONFERENCE (CSTIC 2017), 2017,
  • [9] Risk analysis for the supplier selection problem using failure modes and effects analysis (FMEA)
    Li, Simon
    Zeng, Wei
    JOURNAL OF INTELLIGENT MANUFACTURING, 2016, 27 (06) : 1309 - 1321
  • [10] Risk analysis for the supplier selection problem using failure modes and effects analysis (FMEA)
    Simon Li
    Wei Zeng
    Journal of Intelligent Manufacturing, 2016, 27 : 1309 - 1321