Imaging bolometers for visualization of plasma radiation and cross-validation of three dimensional impurity transport models for the large helical device

被引:0
作者
机构
[1] National Institute for Fusion Science, Toki 509-5292
[2] Kurchatov Institute
[3] Graduate University for Advanced Studies, Toki 509-5292
来源
Peterson, B.J. (peterson@LHD.nifs.ac.jp) | 1600年 / Japan Society of Plasma Science and Nuclear Fusion Research卷 / 08期
关键词
Bolometer; Imaging; LHD; Plasma radiation; Synthetic instrument;
D O I
10.1585/pfr.8.2402037
中图分类号
学科分类号
摘要
The InfraRed imaging Video Bolometer (IRVB) measures the radiation from the plasma in two dimensions, giving an image of the plasma radiation power loss. Using a geometry matrix calculated from a model of the LHD first wall, the IRVB sightline geometry and a three dimensional (3D) plasma grid, a synthetic instrument is developed using the 3D carbon impurity radiation results of the EMC3-EIRENE edge impurity transport code as an input. The output of the synthetic instrument are images of the plasma radiation at the IRVB foil due to the EMC3-EIRENE code, which are qualitatively compared with preliminary experimental images from the IRVB. Such a comparison for detached discharges in LHD in which an externally induced m/n = 1/1 magnetic island is applied shows that when the magnetic island is moved 36 degrees toroidally the enhanced radiation in the x-points of the magnetic island also moves as predicted by the EMC3-EIRENE code. © 2013 The Japan Society of Plasma Science and Nuclear Fusion Research.
引用
收藏
相关论文
共 8 条
  • [1] Mast K.F., Et al., Rev. Sci. Instrum., 62, (1991)
  • [2] Peterson B.J., Rev. Sci. Instrum., 71, (2000)
  • [3] Peterson B.J., Et al., Rev. Sci. Instrum., 74, (2003)
  • [4] Feng Y., Et al., Contrib. Plasma Phys., 44, (2004)
  • [5] Reiter D., Et al., Fusion Sci. Technol., 47, (2005)
  • [6] Kobayashi M., Et al., Phys. Plasmas, 17, (2010)
  • [7] Peterson B.J., Et al., J. Nucl. Mater., 415, (2011)
  • [8] Drapiko E.A., Et al., Nucl. Fusion, 51, (2011)