Simplified single neuron model for robust local pulse wave velocity sensing using a tetherless bioimpedance device

被引:0
作者
Hong, Sungcheol [1 ,2 ]
Hsiao, Chin-To [1 ,2 ]
Cote, Gerard L. [1 ,2 ,3 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Engn Expt Stn, Ctr Remote Hlth Technol & Syst, College Stn, TX 77843 USA
[3] Texas A&M Univ, Dept Elect Engn, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
Pulse transit time; Pulse wave velocity; Bioimpedance; Cuffless blood pressure; BLOOD-PRESSURE; TRANSIT-TIME; ARRIVAL-TIME; STIFFNESS; MARKER; DESIGN; SKIN;
D O I
10.1016/j.bios.2024.116793
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pulse arrival time (PAT), Pulse transit time (PTT), and Pulse Wave Velocity (PWV) have all been used as metrics for assessing a number of cardiovascular applications, including arterial stiffness and cuffless blood pressure monitoring. These have been measured using various sensing methods, including electrocardiogram (ECG) with photoplethysmogram (PPG), two PPG sensors, or two Bioimpedance (BioZ) sensors. Our study addresses the mathematical inaccuracies of previous bioimpedance approaches and incorporates PTT weights for the peak- peak (PTTpp), middle-middle (PTTmm), and foot-foot (PTTff) segments of the sensing signal into a single neuron model to determine a more accurate and stable PWV. In addition, we developed a tetherless bioimpedance device and compared our PTT estimation approaches, which yielded PWV across six subjects and two different arteries. Specifically, using our model, we found that the most reliable combination of weights corresponding to PTTpp, PTTmm, and PTTff was (0.260, 0.704, 0.036) for the brachial artery and (0.104, 0.858, 0.038) for radial artery. This model consistently yielded stable values across repetitions, with PWV values of 5.2 m/s, 5.3 m/s, and 5.9 m/s for the brachial artery and values of 5.8 m/s, 6.6 m/s, and 6.5 m/s for the radial artery. This system and model offer the possibility of obtaining higher reliability PTT and PWV values yielding better monitoring of cardiovascular health measures such as blood pressure and arterial stiffness.
引用
收藏
页数:11
相关论文
共 96 条
  • [1] Aggarwal Charu C., 2005, P 31 INT C VER LARG, P901, DOI DOI 10.5555/1083592.1083696
  • [2] Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
    Al-harosh, Mugeb
    Yangirov, Marat
    Kolesnikov, Dmitry
    Shchukin, Sergey
    [J]. SENSORS, 2021, 21 (24)
  • [3] Andrew M., 2001, ICML 01 P 18 INT C M, V2001, P282, DOI [10.29122/mipi.v11i1.2792, DOI 10.29122/MIPI.V11I1.2792]
  • [4] Brachial and Radial Systolic Blood Pressure Are Not the Same Evidence to Support the Popeye Phenomenon
    Armstrong, Matthew K.
    Schultz, Martin G.
    Picone, Dean S.
    Black, J. Andrew
    Dwyer, Nathan
    Roberts-Thomson, Philip
    Sharman, James E.
    [J]. HYPERTENSION, 2019, 73 (05) : 1036 - 1041
  • [5] Reflecting on posture
    Avolio, Alberto
    Parati, Gianfranco
    [J]. JOURNAL OF HYPERTENSION, 2011, 29 (04) : 655 - 657
  • [6] Racial Differences in Arterial Stiffness are Mainly Determined by Blood Pressure Levels: Results From the ELSA-Brasil Study
    Baldo, Marcelo P.
    Cunha, Roberto S.
    Ribeiro, Antonio L. P.
    Lotufo, Paulo A.
    Chor, Dora
    Barreto, Sandhi M.
    Bensenor, Isabela M.
    Pereira, Alexandre C.
    Mill, Jose Geraldo
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (06):
  • [7] Digital medicine and the curse of dimensionality
    Berisha, Visar
    Krantsevich, Chelsea
    Hahn, P. Richard
    Hahn, Shira
    Dasarathy, Gautam
    Turaga, Pavan
    Liss, Julie
    [J]. NPJ DIGITAL MEDICINE, 2021, 4 (01)
  • [8] Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Bilo, Grzegorz
    Zorzi, Cristina
    Munera, Juan E. Ochoa
    Torlasco, Camilla
    Giuli, Valentina
    Parati, Gianfranco
    [J]. BLOOD PRESSURE MONITORING, 2015, 20 (05) : 291 - 294
  • [9] Conventional pulse transit times as markers of blood pressure changes in humans
    Block, Robert C.
    Yavarimanesh, Mohammad
    Natarajan, Keerthana
    Carek, Andrew
    Mousavi, Azin
    Chandrasekhar, Anand
    Kim, Chang-Sei
    Zhu, Junxi
    Schifitto, Giovanni
    Mestha, Lalit K.
    Inan, Omer T.
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] I Luso-Brazilian Positioning on Central Arterial Pressure
    Brandao, Andrea A.
    Amodeo, Celso
    Alcantara, Cristina
    Barbosa, Fduardo
    Nobre, Fernando
    Pinto, Fernando
    Vilela-Martin, Jose Fernando
    Bastos, Jose Mesquita
    Yugar-Toledo, Juan Carlos
    Mota-Gomes, Marco Antonio
    Toros Neves, Mario Fritsch
    Bolivar Malachias, Marcus Vinicius
    Rodrigues, Manuel de Carvalho
    Passarelli Junior, Oswaldo
    Veiga Jardim, Paulo Cesar B.
    Cunha, Pedro Guimaraes
    Povoa, Rui
    Fonseca, Teresa
    Dias, Vitor Paixao
    Barroso, Weimar Sebba
    Oigman, Wille
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2017, 108 (02) : 100 - 108