Lightning overvoltage analysis according to interval of arrester and overhead grounding wire in DC distribution system

被引:1
|
作者
机构
[1] An, Chun-Yong
[2] Lee, Jong-Beom
[3] Kim, Yong-Kap
来源
Lee, J.-B. (ipower@wku.ac.kr) | 1600年 / Korean Institute of Electrical Engineers卷 / 62期
关键词
Electrolysis;
D O I
10.5370/KIEE.2013.62.4.474
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Analysis of Lightning Overvoltage according to the Location of Overhead Ground Wire in Korea Distribution System
    Han, Jun
    Seo, Hun-Chul
    Kim, Chul-Hwan
    2012 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2012, : 1274 - 1276
  • [2] Analysis of effect on lightning surge according to the grounding condition of overhead ground wire in distribution system
    Han, Joon
    Kim, Chul-Hwan
    Seo, Hun-Chul
    Choi, Sun-Kyu
    Lee, Byung-Sung
    Transactions of the Korean Institute of Electrical Engineers, 2014, 63 (03): : 331 - 337
  • [3] Analysis of lightning overvoltage according to grounding method and corona effect of lightning arrester in wind farm
    Kim J.-H.
    Kim K.-H.
    Woo J.-W.
    Transactions of the Korean Institute of Electrical Engineers, 2019, 68 (02): : 235 - 240
  • [4] Lightning Overvoltage Analysis of Wind Turbine for Lightning Protection according to Grounding Method of Specification KEC
    Pyo K.-J.
    Lee T.-K.
    Kim K.-H.
    Kim J.-H.
    Woo J.-W.
    Kim, Kyu-Ho (kyuho@hknu.ac.kr), 1600, Korean Institute of Electrical Engineers (69): : 529 - 533
  • [5] Lightning Protection System on Overhead Distribution Line Using Multi Chamber Arrester
    Perdana, Erlangga
    Hidayat, Syarif
    Zoro, Reynaldo
    2014 INTERNATIONAL CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2014, : 70 - 74
  • [6] Calculation of lightning induced overvoltage on overhead distribution lines
    Beijing Key Laboratory of High Voltage and EMC , Changping District, Beijing 102206, China
    不详
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2012, 31 (191-199):
  • [7] Improvement of Protection System against Wire Break caused by Lightning Overvoltage in DC Traction System
    Shibata, Naoki
    Morimoto, Hiroaki
    Yoshii, Tsurugi
    Uematsu, Syouji
    Hayashiya, Hitoshi
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1021 - 1026
  • [8] An analysis and comparison of lightning induced overvoltage according to isolation and common grounding system of large-scale photovoltaic power plant in lightning strikes
    Lee C.-U.
    Kim J.-C.
    Transactions of the Korean Institute of Electrical Engineers, 2019, 68 (08): : 1017 - 1024
  • [9] FDTD Analysis of the Electric Field of a Substation Arrester Under a Lightning Overvoltage
    Imato, Shunsuke
    Baba, Yoshihiro
    Nagaoka, Naoto
    Itamoto, Naoki
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2016, 58 (02) : 615 - 618
  • [10] Lightning analysis of grounding system in wind farms: Comparison between interconnected overhead ground wire and underground bare cables
    da Silva, Wagner Costa
    de Azevedo, Walter Luiz Manzi
    D'Annibale, Jose Luciano Aslan
    de Araujo, Anderson Ricardo Justo
    Pissolato Filho, Jose Pissolato
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 242