The relationship between respiratory variation in the pulmonary arterial pressure tracing and intra-thoracic pressure changes: A pilot study

被引:1
作者
机构
[1] Department of Anesthesiology, University of Virginia Health Sciences Center, Charlottesville, VA 22908-0710
来源
Thiele, R.H. (thiele@virginia.edu) | 1600年 / Informa Healthcare卷 / 37期
关键词
Fluid responsiveness; Haemodynamics; Respiratory variation;
D O I
10.3109/03091902.2013.789564
中图分类号
学科分类号
摘要
Respiratory variation in the systemic arterial blood pressure tracing is predictive of the change in cardiac output following volume administration. However, significant inter-individual variability exists. Animal data suggest that systemic arterial respiratory variation loses its predictive ability in the setting of right ventricular failure. Human studies suggest that patients with elevated pulmonary artery pressures are relatively unresponsive to volume administration. The current respiratory variation paradigm neglects the haemodynamic contribution of the right ventricular system. The goal of this study was to determine whether respiratory variation in the pulmonary arterial system could be attributed to intra-thoracic pressure changes. Systemic (radial) and pulmonary arterial pressure waveforms as well as all ventilatory variables were extracted from a haemodynamic database. Using a fast Fourier transformation, the ratio of respiratory (0.15-0.5 Hz) to cardiac (0.67-3 Hz) power was calculated every minute for both arterial waveforms, yielding two 'spectral power ratios' (SPoR). SPoR was compared to all available ventilatory parameters using a linear regression technique. From 19 patients 3422 min of data was analysed. There were statistically significant (p < 0.05) but clinically insignificant correlations between SPoRradial and mean airway pressure (r = -0.0462) and minute ventilation (r = -0.130). All tested correlations between SPoRpulmonary and ventilatory parameters were statistically significant, with correlations ranging from 0.112-0.224 (median 0.194). The correlation between SPoRpulmonary and SPoRradial was stronger than the correlation between either measure of respiratory variation and any of the ventilatory parameters (r = 0.342, p < 0.001). Respiratory variation in the pulmonary arterial tracing does not appear to be closely related to ventilatory parameters and is more closely related to systemic arterial respiratory variation, a well-validated estimate of volume status. The observed respiratory variation in the pulmonary arterial pressure tracing may be related to cyclical changes in pre-load or after-load that occur with mechanical ventilation and may affect the predictive power of systemic arterial respiratory variation. © 2013 Informa UK Ltd.
引用
收藏
页码:252 / 258
页数:6
相关论文
共 13 条
[1]  
Marik P.E., Cavallazzi R., Vasu T., Hirani A., Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature, Critical Care Medicine, 37, pp. 2642-2647, (2009)
[2]  
Cannesson M., Le Manach Y., Hofer C.K., Goarin J.P., Lehot J.J., Vallet B., Tavernier B., Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: A ''Gray Zone'' approach, Anesthesiology, 115, pp. 231-241, (2011)
[3]  
Daudel F., Tuller D., Krahenbuhl S., Jakob S.M., Takala J., Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: An experimental study, Critical Care, 14, 3, (2010)
[4]  
Wyler Von Ballmoos M., Takala J., Roeck M., Porta F., Tueller D., Ganter C.C., Schroder R., Bracht H., Baenziger B., Jakob S.M., Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: A clinical study, Critical Care, 14, 3, (2010)
[5]  
Michard F., Richards G., Biais M., Lopes M., Auler J.O., Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure?, Critical Care, 14, (2010)
[6]  
Jones D., Egi M., Baldwin I., Bellomo R., A pilot study of the effect of altering airway pressure on systolic pulse pressure variation in the systemic and pulmonary arterial circulations, Critical Care and Resuscitation, 6, pp. 167-174, (2004)
[7]  
Kleinman B., Understanding natural frequency and damping and how they relate to the measurement of blood pressure, Journal of Clinical Monitoring, 5, pp. 137-147, (1989)
[8]  
Szold A., Pizov R., Segal E., Perel A., The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs, Intensive Care Medicine, 15, pp. 368-371, (1989)
[9]  
Suehiro K., Okutani R., Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation, Journal of Anesthesia, 25, 5, pp. 777-780, (2011)
[10]  
Morey T.E., Gravenstein N., Rice M.J., Let's think clinically instead of mathematically about device accuracy, Anesthesia & Analgesia, 113, pp. 89-91, (2011)