Selection of MCP for array X-ray pulsar navigation detector

被引:4
作者
Song, Juan [1 ,2 ]
Zhao, Bao-Sheng [1 ]
Sheng, Li-Zhi [1 ]
Liu, Zhe [1 ]
Liu, Yong-An [1 ]
机构
[1] State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an
[2] University of Chinese Academy of Sciences, Beijing
来源
Guangxue Jingmi Gongcheng/Optics and Precision Engineering | 2015年 / 23卷 / 02期
关键词
Count rate; MCP selection; Microchannel Plate (MCP); Pulsar navigation system; Pulse amplitude; Single photon detection; X-ray detector;
D O I
10.3788/OPE.20152302.0402
中图分类号
学科分类号
摘要
According to the demands of an array detector in the X-ray pulsar navigation system for Micro-channel Plate (MCP), a selection method for the MCP was explored. Four key parameters for the selection of MCPs, the uniformity of gain, impedance matching, dark count rate and the gain coefficient were determined. Based on the four key parameters, corresponding experiments were designed and the selection process of MCPs was set out. The amplitudes and counting rates of MCPs selected by proposed method were tested. The tested results show that the relative error of each detection unit is not identical. When a single channel anode is used, the ranges of the maximum relative error Δ1i and minimum relative error Δ2i of the amplitudes for output signals from the ith anode are 7%-13.5% and 3%-6.7%, respectively, and when a four-channel anode is used, Δ1i and Δ2i are 7.8% and 3.1%, respectively. Moreover, the relative error between the anode count rate n1+n2+n3+n4 from the single channel and N from the four-channel shared anode is 4.38%, less than 10%. Obtained results indicate that the MCPs with good performance have been effectively chosen by the proposed selection method. ©, 2015, Chinese Academy of Sciences. All right reserved.
引用
收藏
页码:402 / 407
页数:5
相关论文
共 15 条
[1]  
Cheng J.X., Wen T.Sh., Zhu Z.Y., Et al., Developing progress of multiframe gated microchannel plate X ray camera, Opt. Precision Eng., 4, 1, pp. 44-48, (1996)
[2]  
Li M., Fan X.H., Ni Q.L., Et al., Quantum efficiency of microchannel plate in 12~40 nm, Opt. Precision Eng., 16, 1, pp. 1-5, (2008)
[3]  
Pan J.Sh., Lu J.W., Li Y.H., Et al., Exploring the feasibility and approach for unfilmed-microchannel-plate based third generation image intensifiers, Acta Optica Sinica, 32, 3, (2012)
[4]  
Loeney D.P., Heimann P.A., Padmore H.A., Et al., Characterization of CsI photocathodes at grazing incidence for use a unit quantum efficiency x ray streak camera, SPIE, 5194, pp. 139-148, (2004)
[5]  
Zheng Y., Peng Z., Bo D., Et al., Spectral sensitivity calibration of Au and CsI photocathodes of high speed X ray scanning camera, SPIE, 8419, (2012)
[6]  
Ni Q.L., Han S.L., Chen B., Et al., Quantum detection effiency of spherical microchannel plate in extreme ultraviolet, Opt. Precision Eng., 19, 11, pp. 2596-2601, (2011)
[7]  
Huang Y., Zhang X.F., Yu X., Pipeline filtering detection of stationary point targets in photon images, Chinese Optics, 6, 1, pp. 73-79, (2013)
[8]  
Bu Sh.F., Ni Q.L., He L.P., Et al., Microchannel plate photon counting detector in UV range, Chinese Optics, 5, 3, pp. 302-309, (2012)
[9]  
Hu H.J., Zhao B.Sh., Sheng L.Zh., Et al., A simulation experiment system for X ray pulsar based navigation, Acta Phys. Sin., 60, 2, (2011)
[10]  
Zhang W.W., Light weight and high angular resolution X-ray optics for astronomy, SPIE, pp. 1-11, (2011)