Design of sub-synchronous oscillation proportional resonance damping controller for doubly-fed wind turbines based on impedance analysis

被引:0
|
作者
Qin, Shiyao [1 ]
Wang, Zehui [2 ,3 ]
Li, Shaolin [1 ]
Chen, Renjie [3 ,4 ]
Jia, Lingjie [2 ,3 ]
Peng, Xiaotao [2 ,3 ]
机构
[1] China Elect Power Res Inst, Beijing, Peoples R China
[2] Wuhan Univ, Sch Elect Engn & Automat, Hubei Key Lab Power Equipment & Syst Secur Integra, Wuhan, Peoples R China
[3] Wuhan Univ, Sch Elect Engn & Automat, Wuhan, Peoples R China
[4] Wuhan Iron & Steel Design & Res Inst, Wuhan, Peoples R China
关键词
Sub-synchronous oscillation; Parameter tuning; Doubly fed induction generators; Oscillation monitoring; Damping control; FARMS;
D O I
10.1016/j.ijepes.2024.110333
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Doubly fed induction generators are widely used in wind power generation because of their efficient and low-cost power generation and active-reactive power decoupling control features. For the problem of sub-synchronous oscillation generated by the grid-connected doubly-fed wind turbine through series compensation line, this paper firstly carries out the eigenvalue participation factor analysis of the small signal model including the multiphysical control links of grid-connected system, and an impedance model is constructed for the quantitative analysis of the sub-synchronous oscillation damping characteristics. Applying impedance analysis on the above model, it is concluded that the negative equivalent resistance under the resonant frequency is the cause of subsynchronous oscillation. Then a controller was designed that uses a high-pass filter in series with a proportionalresonant link to generate an additional oscillation damping component in the rotor winding modulation voltage. Based on the analysis of how controller parameters affect the impedance characteristics, the inequality constraint conditions for the parameter design to optimize the controller's impedance compensation characteristics and robustness to oscillation frequency is proposed. Finally, the oscillation suppression effect of the controller is analyzed by time domain simulation and it is tested that the controller can suppress sub-synchronous oscillation and has adaptability in scenarios with different parameters.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Mitigation of Sub-synchronous Resonance in Doubly Fed Induction Generator Based Wind Energy System
    Ratna, Ankita
    Pachauri, Rupendra Kumar
    Chauhan, Yogesh K.
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [22] Modeling and control of Type-2 wind turbines for sub-synchronous resonance damping
    Mancilla-David, Fernando
    Luis Dominguez-Garcia, Jose
    De Prada, Mikel
    Gomis-Bellmunt, Oriol
    Singh, Mohit
    Muljadi, Eduard
    ENERGY CONVERSION AND MANAGEMENT, 2015, 97 : 315 - 322
  • [23] Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines
    Leon, Andres E.
    Solsona, Jorge A.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) : 419 - 428
  • [24] Fuzzy Logic Based SSSC as Sub-Synchronous Resonance Damping Controller
    Prasad, Chinnari Eswar
    Vadhera, Shelly
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,
  • [25] Sub-synchronous control interaction in power grids including doubly fed induction generator based wind turbines
    Azizi, Amir Hossein
    Rahimi, Mohsen
    IET RENEWABLE POWER GENERATION, 2022, 16 (15) : 3197 - 3215
  • [26] Design of Sub-synchronous Oscillation Damping Controller in MMC-MTDC for SSO Suppression
    Li, Shupeng
    Huo, Xianxu
    Liu, Yun
    Yu, Guangyao
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 290 - 294
  • [27] Proposed sub-synchronous resonance damping controller for large-scale wind farms
    Moradi-Shahrbabak, Zahra
    IET RENEWABLE POWER GENERATION, 2023, 17 (13) : 3209 - 3220
  • [28] A Novel Unified Power Flow Controller with Sub-Synchronous Oscillation Damping
    Zadeh, Mehdi Karbalaye
    Lesani, Hamid
    Farhangi, Shahrokh
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (05): : 2386 - 2400
  • [29] Optimization Control of Sub-Synchronous Oscillations in Doubly Fed Generators with Wind Turbines Using the Genetic Algorithm
    Zhang, Xu
    Xie, Yuhan
    Xie, Qiman
    Huang, Hui
    Gao, Lintao
    Ye, Jun
    Ma, Shenbing
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [30] Fuzzy Logic Controller for Damping Sub-synchronous Oscillation in Power System
    Shoulaie, A.
    poodeh, M. Bayati
    Shahgholian, Gh.
    Zaeri, A. H.
    ICIAS 2007: INTERNATIONAL CONFERENCE ON INTELLIGENT & ADVANCED SYSTEMS, VOLS 1-3, PROCEEDINGS, 2007, : 887 - +