Performance and Applicability Analysis of Indirect Evaporative Cooling Units in Data Centers Across Various Humidity Regions

被引:0
|
作者
Wei, Qian [1 ]
Lu, Jun [1 ]
Xia, Xiaoping [2 ]
Zhang, Bin [3 ]
Ying, Xiang [1 ]
Li, Leihong [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Southern Power Grid Integrated Energy Co, Guangzhou 510635, Peoples R China
[3] Yue Neng Bldg, 45-6 Tianhe Rd, Guangzhou 510075, Peoples R China
关键词
data center; fresh-air indirect heat transfer; coefficient of performance; indirect evaporative cooling; power-usage effectiveness;
D O I
10.3390/buildings14113623
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indirect evaporative cooling (IEC), which utilizes natural cooling sources, is an advanced and promising technology to reduce the energy consumption of cooling systems in a data center (DC). This study presents a model of an IEC air-conditioning unit in a DC using TRNSYS simulation software validated using actual operational data to investigate the adaptability of IEC units in data centers located in regions with varying humidity levels, providing a reference for their application and promotion in DCs. Based on this premise, the authors analyzed the meteorological characteristics of Urumqi (a dry region), Beijing (a region with medium humidity), and Shanghai (a region with high humidity), which are representative cities in different humidity zones. The analysis identified the annual operating hours of the unit's three operation modes, including fresh-air indirect heat transfer (FAIHT), IEC, and hybrid. Simultaneously, the authors conducted a simulation of the unit's yearly energy consumption and determined time change curves for annual energy consumption, hourly coefficient of performance (COP) throughout the year, and mechanical cooling in various locations. The results indicate that IEC air-conditioning systems are highly effective in promoting the efficiency of data centers in various humidity regions. Dry locations demonstrate the greatest adaptability, followed by regions with medium humidity and, finally, regions with high humidity. The findings indicate that IEC units provide significant energy efficiency and cost-effectiveness when deployed in typical urban DCs across various humidity zones in China. The average annual power-usage effectiveness (PUE) of each city's DC utilizing the unit is less than 1.3, and the unit's annual operational cost savings exceed 30%.
引用
收藏
页数:25
相关论文
共 34 条
  • [1] Climatic applicability of indirect evaporative cooling strategies for data centers in China
    Cui, Xin
    Yang, Chuanjun
    Yan, Weichao
    Wang, Xinyu
    Liu, Yahui
    Jin, Liwen
    JOURNAL OF BUILDING ENGINEERING, 2024, 83
  • [2] Feasibility Analysis of Indirect Evaporative Cooling System Assisted by Liquid Desiccant for Data Centers in Hot-Humid Regions
    Shi, Wenchao
    Ma, Xiaochen
    Min, Yunran
    Yang, Hongxing
    SUSTAINABILITY, 2024, 16 (05)
  • [3] DESIGN ANALYSIS AND PERFORMANCE EVALUATION OF A DATA CENTER WITH INDIRECT EVAPORATIVE COOLING
    Tavakkoli, Fatemeh
    Ebrahimi, Siavash
    Sun, Xiaogang
    Cui, Yan
    Heydari, Ali
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2017, 2017,
  • [4] NEURAL NETWORK BASED BIN ANALYSIS FOR INDIRECT/DIRECT EVAPORATIVE COOLING OF MODULAR DATA CENTERS
    Walekar, Abhishek
    Siddarth, Ashwin
    Guhe, Abhishek
    Sukthankar, Nikita
    Agonafer, Dereje
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6A, 2019,
  • [5] Indirect Evaporative cooling systems: modelling and performance analysis
    Liberati, Paolo
    De Antonellis, Stefano
    Leone, Calogero
    Joppolo, Cesare Maria
    Bawa, Yakub
    BEYOND NZEB BUILDINGS, 2017, 140 : 475 - 485
  • [6] Analysis of principle, performance and applicability of indirect evaporative water chiller
    Chang J.
    Huang X.
    An M.
    Li Z.
    Huagong Xuebao/CIESC Journal, 2020, 71 : 236 - 244
  • [7] INDIRECT EVAPORATIVE PRE-COOLED COMPRESSOR COOLING SYSTEM PERFORMANCE UNDER VARIOUS OUTDOOR AIR HUMIDITY CONDITIONS
    Brahmanis, Arturs
    Lesinskis, Arturs
    CIVIL ENGINEERING '13, PT I, 2013, 4 : 212 - 216
  • [8] Field test of cooling systems in two air-cooled data centers: Various regions, air distributions and evaporative cooling technologies
    Jing, Yang
    Xie, Linfeng
    Li, Fangling
    Zhan, Ziyang
    Wang, Zhenghua
    Yang, Fan
    Fan, Jiale
    Zhu, Zihan
    Zhang, Hao
    Zhao, Ce
    Shi, Zhuofan
    Jiang, Haihua
    Xie, Xiaoyun
    Jiang, Yi
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [9] Performance Investigation on the Thermosyphon with Evaporative Condenser for Free Cooling of Data Centers
    Liu, Haichao
    Shao, Shuangquan
    Zhang, Hainan
    Tian, Changqing
    JOINT INTERNATIONAL CONFERENCE ON ENERGY, ECOLOGY AND ENVIRONMENT ICEEE 2018 AND ELECTRIC AND INTELLIGENT VEHICLES ICEIV 2018, 2018,
  • [10] Evaporative cooling of gas turbine engines - Climatic analysis and application in high humidity regions
    Chaker, Mustapha
    Meher-Homji, Cyrus B.
    PROCEEDINGS OF THE ASME TURBO EXPO, VOL 3, 2007, : 761 - 773