Voltammetric determination of lead (II) ions at carbon paste electrode modified with banana tissue

被引:0
|
作者
Institute of Chemistry, University of the Philippines, Los Baños, Philippines [1 ]
机构
[1] Institute of Chemistry, University of the Philippines, Los Baños
来源
J. Appl. Sci. | 2007年 / 9卷 / 1286-1292期
关键词
Banana tissue; Carbon paste electrode; Lead; Modifier;
D O I
10.3923/jas.2007.1286.1292
中图分类号
学科分类号
摘要
Banana tissue contains materials with functional groups which have the ability to form complexes with metal ions. With this property, banana tissue was used as modifier of carbon paste electrode for voltammetric determination of lead ions in aqueous samples. The use of 0.01 M HCl as supporting electrolyte and 20% (w/w) modifier gave an optimum current response for lead (II) solution. Accumulation time of 6 min, accumulating solution of pH 5, deposition time of 300 sec and deposition potential of-1500 mV were found to give the best results in the analysis of lead (II). Multiple stripping of the used electrode successfully removed lead ions for the regeneration of the electrode. The banana modified carbon paste electrode exhibited a sensitivity of 2.81 μA/ppm and a limit of detection (LOD) of 0.10 mg L-1. © 2007 Asian Network for Scientific Information.
引用
收藏
页码:1286 / 1292
页数:6
相关论文
共 50 条
  • [31] Catalytic adsorptive stripping voltammetric determination of copper(II) on a carbon paste electrode
    Ning Liu
    Jun-Feng Song
    Analytical and Bioanalytical Chemistry, 2005, 383 : 358 - 364
  • [32] Catalytic adsorptive stripping voltammetric determination of copper(II) on a carbon paste electrode
    Liu, N
    Song, JF
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 358 - 364
  • [33] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Vesna Antunović
    Tatjana Tripković
    Biljana Tomašević
    Rada Baošić
    Dijana Jelić
    Aleksandar Lolić
    Analytical Sciences, 2021, 37 (2) : 353 - 358
  • [34] Electrochemical Behavior and Voltammetric Determination of a Manganese(II) Complex at a Carbon Paste Electrode
    Karastogianni, Sophia
    Girousi, Stella
    ANALYTICAL CHEMISTRY INSIGHTS, 2016, 11 : 1 - 11
  • [35] Anodic stripping voltammetric determination of silver ion at a carbon paste electrode modified with carbon nanotubes
    Javad Tashkhourian
    Sana Javadi
    Fatemeh Nami Ana
    Microchimica Acta, 2011, 173 : 79 - 84
  • [36] Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode
    Jia, Shaohui
    Gong, Shixing
    Cheng, Yong
    Wang, Huiyun
    Liu, Hejian
    Zhang, Bo
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (11) : 1217 - 1222
  • [37] Anodic stripping voltammetric determination of silver ion at a carbon paste electrode modified with carbon nanotubes
    Tashkhourian, Javad
    Javadi, Sana
    Ana, Fatemeh Nami
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 79 - 84
  • [38] Voltammetric determination of quercetin in urine at carbon paste electrode
    Farghaly, OA
    ANALYTICAL LETTERS, 2005, 38 (13) : 2247 - 2258
  • [39] Poly(amoxicillin) Modified Carbon Paste Electrode for the Determination of Dopamine: A Cyclic Voltammetric Study
    Rekha
    Swamy, Bahaddurghatta Eshwaraswamy Kumara
    Ganesh, Pattan Siddappa
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (02): : 184 - 192
  • [40] Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Kolbadinezhad, Mansureh
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (09) : 1411 - 1416