IMPACT OF CHANGE IN COAL QUALITY ON OPERATING PARAMETERS OF THERMAL POWER PLANT STANARI AND ITS RISK ASSESSMENT

被引:0
作者
Jakovljevic, Ivica Z. [1 ]
Lazarevic, Marko M. [2 ]
Pavlovic, Natalija, V [3 ]
Subaranovic, Tomislav Z. [3 ]
Petrovic, Milenko, V [1 ]
机构
[1] Univ Pristina, Fac Tech Sci Kosovska Mitrov, Pristina, Serbia
[2] EFT Mine & Thermal Power Plant Stanari, Stanari, Bosnia & Herceg
[3] Univ Belgrade, Fac Min & Geol, Belgrade, Serbia
来源
THERMAL SCIENCE | 2024年 / 28卷 / 6A期
关键词
risk assessment; opencast mine; coal quality; thermal power plant; energy efficiency;
D O I
10.2298/TSCI240224120J
中图分类号
O414.1 [热力学];
学科分类号
摘要
The technical and technological characteristics ofthe Stanari Power Plant block were designed based on the results of the analysis of coal samples from the Raskovac opencast mine. There have not been any notable variations in the coal quality during the Stanari thermal power plants' present operating term from the projects' stated values. For the expected lifetime of mine, i.e., the thermal power plant operation until 2050, it is necessary to unearth the total remaining available coal reserves from the Stanari basin. The thermal power plants' operation may be significantly impacted by variations in coal quality at the Ostruznja opencast mine. The use of coal with quality parameters lower than designed can cause problems in the operation of the boiler, stoppages in operation, and an increased volume of maintenance and overhaul of the boiler. Coal quality control in the process of sampling, mining, transportation, and depositing of coal must be at a level that enables smooth operation of the thermal power plant. This paper presents test results during the operation of the thermal power plant burning coal of different quality, (lower calorific value in range from 9100 kJ/kg to <= 7500 kJ/kg), a risk assessment of long-term planning, and the effectiveness and economy of the thermal power plant operation. The potential economic effects and reliability of the operation of thermal power plants due to the increased consumption of coal, limestone and self-consumption in operating modes with significantly lower coal quality than designed were analyzed in particular.
引用
收藏
页码:4565 / 4578
页数:14
相关论文
共 16 条
[1]  
[Anonymous], Janjic, I. 1996: MSc Thesis. University of Belgrade, Faculty of Mining and Geology (In Serbian)
[2]  
[Anonymous], 2018, Revista Espacios, V39, P16
[3]  
[Anonymous], 2017, VDI - The Association of German Engineers "
[4]  
[Anonymous], 2020, ASTM D3175-20
[5]  
[Anonymous], 2020, Test Program for the Operation of the Stanari TPP Block when Burning Coal of Different Lower Heat Values
[6]  
[Anonymous], Work Reports and Project Documentation EFT-Mine and Thermal Power Plant Stanari
[7]  
[Anonymous], 2020, Report of Coal Mining of Different LCV for Testing the Work of TPP Stanari
[8]  
Blagojevic T., 2017, P 8 INT C COAL 2017
[9]  
Blagojevic T., 2021, P 10 INT C COAL 2021
[10]  
Dzananovic I., 2015, P 9 INT C QUALITY 20