Implementing a two-stage, shim field-calibrated superconducting shimming method on a 7 T cryogen-free small animal MRI magnet

被引:0
作者
Liu, Jinhao [1 ]
Wang, Yaohui [3 ,4 ]
Wang, Miutian [2 ]
Wang, Wenchen [7 ]
Yang, Gang [5 ]
Wang, Weimin [2 ,5 ,6 ]
Wang, Qiuliang [3 ,4 ]
Liu, Feng [7 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[2] Peking Univ, Sch Elect, Beijing 100871, Peoples R China
[3] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100190, Peoples R China
[4] Chinese Acad Sci, Inst Elect Engn, Div Superconducting Magnet Sci & Technol, Beijing 100190, Peoples R China
[5] Peking Univ, Shenzhen Grad Sch, Inst Biomed Engn, Shenzhen 518055, Peoples R China
[6] Inst Biomed Engn, Shenzhen Bay Lab, Shenzhen 518132, Peoples R China
[7] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
基金
美国国家科学基金会;
关键词
Superconducting shimming; Two-stage method; Ultrahigh field (UHF); Magnetic resonance imaging (MRI); Peak-to-peak homogeneity; HUMAN BRAIN; GRADIENT; DISTORTION; DESIGN;
D O I
10.1016/j.jmr.2024.107787
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ultrahigh field systems (>= 7 T) can increase the signal-to-noise ratio of magnetic resonance imaging (MRI), improving imaging performance compared to systems with lower fields. However, these enhancements heavily rely on a high B 0 magnetic field homogeneity level, which can be achieved through superconducting shimming. This paper presents a novel two-stage superconducting shimming method designed to achieve precise shimming for a 7 T MRI superconducting magnet. In the initial stage, detailed measurements and fittings were conducted to determine the current polarity and the axial or circumferential positions of the shim fields. Subsequently, an optimization strategy was implemented to determine the optimal shim currents with a flexible target field. The second stage involves an iterative process to fine-tune the current of a specific shim coil, identified as having the most significant impact on field homogeneity. The overall fitness of 99.5% underscores the precision in determining the current polarity and position of the shim fields. Significantly, the calibrated shim system substantially improves the peak-to-peak and Root Mean Square Error (RMSE) field homogeneities from 107.42 ppm and 37.00 ppm to 11.12 ppm and 3.26 ppm, respectively, representing improvements of 89.65% and 91.19%. Furthermore, the simulation results of the fine-tuning stage demonstrate additional enhancements in peak-to-peak field homogeneity, to 9.9 ppm by reducing the current of the Z2 shim coil by 51.3 mA. Additionally, the shimmed magnetic field exhibited high time stability, with a maximum variation of only 27 mu T observed within 48 h. Thus, the proposed two-stage superconducting shimming framework effectively addresses the challenge of imperfect B 0 magnetic fields, enhancing peak-to-peak and RMSE field homogeneity. The stepwise optimized approach also mitigates deviations caused by shim-to-shim coupling, demonstrating its efficacy in achieving precise shimming in ultrahigh-field MRI systems.
引用
收藏
页数:11
相关论文
共 51 条
[11]   B0shimming of the human heart at 7T [J].
Hock, Michael ;
Terekhov, Maxim ;
Stefanescu, Maria Roxana ;
Lohr, David ;
Herz, Stefan ;
Reiter, Theresa ;
Ankenbrand, Markus ;
Kosmala, Aleksander ;
Gassenmaier, Tobias ;
Juchem, Christoph ;
Schreiber, Laura Maria .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) :196-210
[12]   Advanced field shimming technology to reduce the influence of a screening current in a REBCO coil for a high-resolution NMR magnet [J].
Iguchi, S. ;
Piao, R. ;
Hamada, M. ;
Matsumoto, S. ;
Suematsu, H. ;
Takao, T. ;
Saito, A. T. ;
Li, J. ;
Nakagome, H. ;
Jin, X. ;
Takahashi, M. ;
Maeda, H. ;
Yanagisawa, Y. .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2016, 29 (04)
[13]   Shimming for the 1020 MHz LTS/Bi-2223 NMR Magnet [J].
Iguchi, Seiya ;
Yanagisawa, Yoshinori ;
Takahashi, Masato ;
Takao, Tomoaki ;
Hashi, Kenjiro ;
Ohki, Shinobu ;
Nishijima, Gen ;
Matsumoto, Shinji ;
Noguchi, Takashi ;
Tanaka, Ryoji ;
Suematsu, Hiroto ;
Saito, Kazuyoshi ;
Shimizu, Tadashi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
[14]   Experimental Study of a Room-Temperature Shimming Technology Employing Genetic Algorithm for NMR/MRI Superconducting Magnets [J].
Jang, Jae Young ;
Hwang, Young Jin ;
Kim, Jaemin ;
Song, Seunghyun ;
Kim, Geonyoung ;
Choi, Kibum ;
Hahn, Seungyong ;
Ahn, Minchul ;
Lee, SangGap .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
[15]   A New Method to Improve Field Uniformity for Application to a Newly Developed 5 T EMPS Superconducting Magnet System [J].
Jang, Jae Young ;
Hwang, Young Jin ;
Kim, Myung Su ;
Choi, Yeon Suk .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (04)
[16]   A High-Resolution Magnetometer Over a Wide Homogeneity Range [J].
Jang, Jae Young ;
Han, Jun Hee ;
Kim, Changsoo ;
Hwang, Young Jin ;
Hahn, Seungyong ;
Ahn, Min Cheol ;
Lee, SangGap .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
[17]   A Feasibility Study of an Optimization-Based Active Field Uniformity Compensation Method for Superconducting Magnets [J].
Jang, Jaeyoung ;
Hwang, Young Jin .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (06)
[18]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[19]   Superconducting magnet designs and MRI accessibility: A review [J].
Jimeno, Marina Manso ;
Vaughan, John Thomas ;
Geethanath, Sairam .
NMR IN BIOMEDICINE, 2023, 36 (09)
[20]   DYNAmic Multi-coIl TEchnique (DYNAMITE) shimming of the rat brain at 11.7 T [J].
Juchem, Christoph ;
Herman, Peter ;
Sanganahalli, Basavaraju G. ;
Brown, Peter B. ;
McIntyre, Scott ;
Nixon, Terence W. ;
Green, Dan ;
Hyder, Fahmeed ;
de Graaf, Robin A. .
NMR IN BIOMEDICINE, 2014, 27 (08) :897-906