Exact Efficient Handling of Interrupted Illumination in Helical Cone-Beam Computed Tomography with Arbitrary Pitch

被引:1
|
作者
Schöndube H. [1 ,2 ]
Stierstorfer K. [2 ]
Noo F. [1 ]
机构
[1] Department of Radiology, University of Utah, Salt Lake City
[2] Siemens Healthcare
基金
美国国家卫生研究院;
关键词
computed tomography (CT); differentiated backprojection; M-lines; redundant data; theoretically-exact and stable image reconstruction;
D O I
10.1016/S1007-0214(10)70006-7
中图分类号
学科分类号
摘要
We present a theoretically-exact and stable computed tomography (CT) reconstruction algorithm that is capable of handling interrupted illumination and therefore of using all measured data at arbitrary pitch. This algorithm is based on a differentiated backprojection (DBP) on M-lines. First, we discuss the problem of interrupted illumination and how it affects the DBP. Then we show that it is possible to take advantage of some properties of the DBP to compensate for the effects of interrupted illumination in a mathematically exact way. From there, we have developed an efficient algorithm which we have successfully implemented. We show encouraging preliminary results using both computer-simulated data and real data. Our results show that our method is capable of achieving a substantial reduction of image noise when decreasing the helix pitch compared with the maximum pitch case. We conclude that the proposed algorithm defines for the first time a theoretically-exact and stable reconstruction method that is capable of beneficially using all measured data at arbitrary pitch. © 2010 Tsinghua University Press.
引用
收藏
页码:36 / 43
页数:7
相关论文
共 50 条
  • [1] Exact Efficient Handling of Interrupted Illumination in Helical Cone-Beam Computed Tomography with Arbitrary Pitch
    Harald Schndube
    Karl Stierstorfer
    Frédéric Noo
    TsinghuaScienceandTechnology, 2010, 15 (01) : 36 - 43
  • [2] High-helical-pitch, cone-beam computed tomography
    Silver, MD
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 847 - 855
  • [3] Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography
    Katsevich, A
    Basu, S
    Hsieh, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3089 - 3103
  • [4] Exact image reconstruction in a helical cone-beam scan with a variable pitch
    Zou, Y
    Pan, XC
    Xia, D
    Wang, G
    Jiang, TZ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4200 - 4203
  • [5] Helical cone-beam tomography
    Turbell, H
    Danielsson, PE
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2000, 11 (01) : 91 - 100
  • [6] Optoelectronic implementation of helical cone-beam computed tomography algorithms
    Madec, Morgan
    Fasquel, Jean-Baptiste
    Uhring, Wilfried
    Joffre, Pascal
    Herve, Yannick
    OPTICAL ENGINEERING, 2008, 47 (05)
  • [7] Metal Artifact Reduction in Helical Cone-beam Computed Tomography
    Tang, Jie
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Cheng, Jianping
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2878 - 2881
  • [8] PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch
    Zou, Y
    Pan, XC
    Xia, D
    Wang, G
    MEDICAL PHYSICS, 2005, 32 (08) : 2639 - 2648
  • [9] A theoretically exact reconstruction algorithm for helical cone-beam differential phase-contrast computed tomography
    Li, Jing
    Sun, Yi
    Zhu, Peiping
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5421 - 5432
  • [10] Practical geometric calibration for helical cone-beam industrial computed tomography
    Zhang, Feng
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Jiang, Hua
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 19 - 35