Dynamic behavior analysis and improved fault ride-through control strategy for DFIGs considering the nonlinear arc resistance of grid faults

被引:0
作者
Yan, Chenguang [1 ]
Liu, Qinzhi [1 ]
Wang, Weixiang [1 ]
Yang, Hongxi [1 ]
Liu, Zhenfeng [1 ]
Zhang, Baohui [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Control strategy; Doubly fed induction generator (DFIG); Dynamic behavior analysis; Fault ride-through (FRT); Nonlinear arc resistance; Real-time digital simulator (RTDS); FED INDUCTION GENERATOR; LOW-VOLTAGE RIDE; WIND TURBINE; CAPABILITY; CONVERTER; LINES; POWER;
D O I
10.1016/j.epsr.2025.111423
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Doubly fed induction generators (DFIGs) are confronted with fault ride through (FRT) issues during grid faults whose fault path resistance often comprises a transition resistance and a time-varying resistance of AC arcs. In existing FRT analyses for DFIGs, the arc resistance is often simplified to a fixed value, whose nonlinear characteristics have been neglected. This paper quantitatively analyzes the arc-induced distortions in the stator voltage, stator flux and rotor electromotive force. Under a severe arc fault, the impact of the additional arc component on the FRT process is found to be nonnegligible. In view of this unique signature, an improved arc component-based FRT control strategy with proposed flux observation and component separation method is developed for enhancing the FRT abilities from multiple perspectives, including overcurrent suppression, reactive power supply, and power and electromagnetic torque oscillation elimination. The correctness of the analysis and the advancement of the approach are demonstrated on real-time digital simulator (RTDS). The findings provide new insights when developing FRT methods based on the separated components and the approach can be universally applicable to FRT scenarios of DFIGs with notably distorted stator voltages.
引用
收藏
页数:11
相关论文
共 42 条
  • [11] Dosoglu M.K., A new approach for low voltage ride through capability in DFIG based wind farm, Int. J. Electr. Power Energy Syst., 83, pp. 251-258, (2016)
  • [12] Dosoglu M.K., Hybrid control approach for low-voltage ride-through capability in doubly-fed induction generator-based wind turbines, Comput. Electr. Eng., 90, (2021)
  • [13] Dosoglu M.K., Enhancement of new rotor resistance unit for doubly fed induction generator-based wind turbines, Comput. Electr. Eng., 90, (2021)
  • [14] Xiang D., Ran L., Tavner P.J., Yang S., Control of a doubly fed induction generator in a wind turbine during grid fault ride through, IEEE Trans. Energy Convers., 21, 3, pp. 652-662, (2006)
  • [15] Zhu R., Chen Z., Wu X., Deng F., Virtual damping flux-based LVRT control for DFIG-based wind turbine, IEEE Trans. Energy Convers., 30, 2, pp. 714-725, (2015)
  • [16] Zhu D., Zou X., Deng L., Huang Q., Zhou S., Kang Y., Inductance-emulating control for DFIG-based wind turbine to ride-through grid faults, IEEE Trans. Power Electron., 32, 11, pp. 8514-8525, (2017)
  • [17] Xiao F., Xia Y., Zhang K., Zhang Z., Yin X., Fault characteristics analysis of DFIGWT in whole LVRT process considering control strategy switching between RSC and crowbar, Int. J. Electr. Power Energy Syst., 145, (2023)
  • [18] Chang Y., Mahseredjian J., Kocar I., Karaagac U., Analytical characterization of DFIG response to asymmetrical voltage dips for efficient design, Electr. Power Syst. Res., 211, (2022)
  • [19] Chang Y., Berger M., Kocar I., Control solution to over-modulation of DFIG converter for asymmetrical fault ride through, IEEE Trans. Sustain. Energy, 15, 1, pp. 703-706, (2024)
  • [20] Geng H., Liu C., Yang G., LVRT capability of DFIG-based WECS under asymmetrical grid fault condition, IEEE Trans. Ind. Electron., 60, 6, pp. 2495-2509, (2013)