EFFECTS OF INITIAL LIQUID HEIGHT AND LIQUID VISCOSITY ON TOTAL GAS HOLDUP IN A BUBBLE COLUMN

被引:2
作者
Kobayashi, Nobuya [1 ]
Kurimoto, Ryo [1 ]
Hayashi, Kosuke [1 ]
Tomiyama, Akio [1 ]
机构
[1] Graduate School of Engineering, Kobe University, Rokkodai, Nada, Kobe
基金
日本学术振兴会;
关键词
bubble column; initial liquid height; liquid viscosity; total gas holdup; two-region model;
D O I
10.1615/MultScienTechn.2022044397
中图分类号
学科分类号
摘要
Effects of the initial liquid height and the liquid viscosity on the total gas holdup in a bubble column were investigated under high superficial gas velocities of 0.20 and 0.30 m/s. The column diameter was 200 mm. The initial liquid height ranged from 400 to 3800 mm. The liquid phase was glycerol– water solutions of 4.4 and 12.3 mPa·s in viscosity. The total gas holdup in the bubble column decreases with increasing the initial liquid height and asymptotically approaches a constant value for each liquid viscosity. The total gas holdup decreases with increasing the liquid viscosity, and its de-crease rate is independent of the initial liquid height and the superficial gas velocity in the present experimental range. A two-region model with a multiplier for the effect of the liquid viscosity agrees well with the total gas holdup data. © 2022 by Begell House, Inc.
引用
收藏
页码:1 / 13
页数:12
相关论文
共 50 条
[31]   EFFECTS OF ALCOHOLS ON GAS HOLDUP AND VOLUMETRIC LIQUID-PHASE MASS-TRANSFER COEFFICIENT IN GEL-PARTICLE-SUSPENDED BUBBLE-COLUMN [J].
SALVACION, JL ;
MURAYAMA, M ;
OHTAGUCHI, K ;
KOIDE, K .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1995, 28 (04) :434-442
[32]   The effect of electrolyte concentration on counter-current gas-liquid bubble column fluid dynamics: Gas holdup, flow regime transition and bubble size distributions [J].
Besagni, Giorgio ;
Inzoli, Fabio .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 118 :170-193
[33]   EFFECTS OF PARTITION PLATES ON GAS HOLDUP IN A BUBBLE-COLUMN WITH AND WITHOUT A DRAFT TUBE [J].
YAMASHITA, F .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1993, 26 (06) :742-744
[34]   Gas holdup in a trayed cold-flow bubble column [J].
Kemoun, A ;
Rados, N ;
Li, F ;
Al-Dahhan, MH ;
Dudukovic, MP ;
Mills, PL ;
Leib, TM ;
Lerou, JJ .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (03) :1197-1205
[35]   Gas-liquid-fiber flow in a cocurrent bubble column [J].
Tang, CZ ;
Heindel, TJ .
AICHE JOURNAL, 2005, 51 (10) :2665-2674
[36]   Gas-phase holdup in a slurry-bubble column [J].
Zhu, JW ;
Trivedi, VH ;
Saxena, SC .
CHEMICAL ENGINEERING COMMUNICATIONS, 1997, 157 :53-64
[37]   Liquid Mixing in a Bubble Column [J].
Shimada, Naoki ;
Saiki, Rina ;
Dhar, Abhinav ;
Mizuta, Kei ;
Tomiyama, Akio .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2012, 45 (09) :632-638
[38]   GAS HOLDUP IN A BUBBLE-COLUMN WITH A SINGLE HOLE ORIFICE [J].
KAWASAKI, H ;
TANAKA, H .
KAGAKU KOGAKU RONBUNSHU, 1995, 21 (03) :588-593
[39]   The effect of superficial gas velocity and aerated liquid height on the spatial distribution of local liquid-phase axial dispersion coefficients in a bubble column [J].
Nedeltchev, S ;
Ookawara, S ;
Ogawa, K .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2005, 38 (01) :1-11
[40]   CFD simulation of effects of the configuration of gas distributors on gas-liquid flow and mixing in a bubble column [J].
Lia, Guang ;
Yang, Xiaogang ;
Dai, Gance .
CHEMICAL ENGINEERING SCIENCE, 2009, 64 (24) :5104-5116