EFFECTS OF INITIAL LIQUID HEIGHT AND LIQUID VISCOSITY ON TOTAL GAS HOLDUP IN A BUBBLE COLUMN

被引:2
作者
Kobayashi, Nobuya [1 ]
Kurimoto, Ryo [1 ]
Hayashi, Kosuke [1 ]
Tomiyama, Akio [1 ]
机构
[1] Graduate School of Engineering, Kobe University, Rokkodai, Nada, Kobe
基金
日本学术振兴会;
关键词
bubble column; initial liquid height; liquid viscosity; total gas holdup; two-region model;
D O I
10.1615/MultScienTechn.2022044397
中图分类号
学科分类号
摘要
Effects of the initial liquid height and the liquid viscosity on the total gas holdup in a bubble column were investigated under high superficial gas velocities of 0.20 and 0.30 m/s. The column diameter was 200 mm. The initial liquid height ranged from 400 to 3800 mm. The liquid phase was glycerol– water solutions of 4.4 and 12.3 mPa·s in viscosity. The total gas holdup in the bubble column decreases with increasing the initial liquid height and asymptotically approaches a constant value for each liquid viscosity. The total gas holdup decreases with increasing the liquid viscosity, and its de-crease rate is independent of the initial liquid height and the superficial gas velocity in the present experimental range. A two-region model with a multiplier for the effect of the liquid viscosity agrees well with the total gas holdup data. © 2022 by Begell House, Inc.
引用
收藏
页码:1 / 13
页数:12
相关论文
共 50 条
  • [21] Effect of foam layer on gas holdup in a bubble column
    Yamashita, F
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1995, 28 (06) : 837 - 840
  • [22] Mixing in a gas/liquid flow countercurrent bubble column
    Bartrand, TA
    Farouk, B
    Haas, CN
    Computational Methods in Multiphase Flow III, 2005, 50 : 35 - 44
  • [23] Dynamic and Gas Holdup Studies in a Bubble Column Bioreactor
    Vinod, A. Venu
    Kumar, R. Naveen
    ENVIRONMENTAL SCIENCE AND TECHNOLOGY, PT 2, 2011, 6 : 384 - 387
  • [24] Gas holdup in bubble column bioreactor degrading phenol
    Rayi N.K.
    Kommareddi N.C.
    Ananthula V.V.
    Journal of Hazardous, Toxic, and Radioactive Waste, 2017, 21 (02)
  • [25] Axial and Radial Gas Holdup in Bubble Column Reactor
    Wagh, Sameer M.
    Ansari, Mohashin E. Alam
    Kene, Pragati T.
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (06) : 1703 - 1705
  • [26] Prediction of gas-phase holdup in a bubble column
    Zhu, JW
    Saxena, SC
    CHEMICAL ENGINEERING COMMUNICATIONS, 1997, 161 : 149 - 161
  • [27] GAS-LIQUID MASS-TRANSFER IN THE BUBBLE COLUMN WITH VISCOELASTIC LIQUID
    SUH, IS
    SCHUMPE, A
    DECKWER, WD
    KULICKE, WM
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 69 (02) : 506 - 512
  • [28] Effects of multiple draft tubes with perforated plates on average gas holdup, volumetric mass transfer coefficient and liquid mixing time in a bubble column
    Kawasaki, Hiroyuki
    Yamamoto, Tatsurni
    KAGAKU KOGAKU RONBUNSHU, 2007, 33 (03) : 208 - 210
  • [29] Numerical simulations of the effect of liquid viscosity on gas-liquid mass transfer of a bubble column with a CFD-PBM coupled model
    Zhang, Huahai
    Guo, Kunyu
    Wang, Yuelin
    Sayyar, Ali
    Wang, Tiefeng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 161 (161)
  • [30] Gas holdup in bubble column with draft tube for gas dispersion into annulus
    Yamashita, F
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1998, 31 (02) : 289 - 294