A new phase alignment method for digital projector in phase measuring profilometry

被引:5
作者
Key Laboratory of Measurement and Control for Complex System of Ministry of Education, Southeast University, Nanjing 210096, China [1 ]
机构
[1] Key Laboratory of Measurement and Control for Complex System of Ministry of Education, Southeast University
来源
Zidonghua Xuebao Acta Auto. Sin. | 2008年 / 11卷 / 1363-1368期
关键词
Optical measurement; Phase alignment; Projected fringe;
D O I
10.3724/SP.J.1004.2008.01363
中图分类号
学科分类号
摘要
A new phase alignment method for digital projector is proposed. In the phase measuring profilometry, a key problem is to project sinusoidal fringes. By the n step phase shifting method, the ideal phase can be obtained by the image of the fringes, then based on the mapping relations of the ideal phase and the actual phase, the phase pattern on the digital projector can be aligned automatically. Experiments show that the proposed method can decrease the error of the projected fringes effectively, and that better sinusoidal fringes can be achieved to improve the measurement precision.
引用
收藏
页码:1363 / 1368
页数:5
相关论文
共 12 条
[1]  
Wang C.-Z., Yi B.-C., Sun Y.-F., Hu Y.-L., An improved 3-D face modeling method based on morphable model, Acta Automatica Sinica, 33, 3, pp. 232-239, (2007)
[2]  
Gai S.-Y., Da F.-P., A new fast phase unwrapping method, Acta Optica Sinica, 28, 2, pp. 259-267, (2008)
[3]  
Lou J.-G., Liu Q.-F., Tan T.-N., Hu W.-M., 3-D model based visual traffic surveillance, Acta Automatica Sinica, 29, 3, pp. 434-449, (2003)
[4]  
Hibino K., Oreb B.F., Farrant D.I., Larkin K.G., Phase shifting for nonsinusoidal waveforms with phase-shift errors, Journal of the Optical Society of America A: Optics and Image Science and Vision, 12, 4, pp. 761-768, (1995)
[5]  
Zeng H., Wu F.-C., Hu Z.-Y., Robot self-localization based on planar laser measurement, Acta Automatica Sinica, 33, 2, pp. 138-144, (2007)
[6]  
Da F.P., Gai S.Y., Flexible three-dimensional measurement technique based on a digital light processing projector, Applied Optics, 47, 3, pp. 377-385, (2007)
[7]  
Gai S.-Y., Da F.-P., A new model of 3-D shape measurement system based on phase measuring profilometry and its calibration, Acta Automatica Sinica, 33, 9, pp. 902-910, (2007)
[8]  
Jiang Y., Yang G.-H., 3-D feature extract method for tool wear based on grating projection, Optics and Precision Engineering, 15, 3, pp. 390-395, (2007)
[9]  
Shao S.-Y., Su X.-Y., Moiré effect in PMP using DLP and its influence on phase measurement, Journal of Sichuan University (Natural Science Edition), 40, 5, pp. 882-887, (2003)
[10]  
Hu Y.S., Xi J.T., Li E.B., Chicharo J., Yang Z.K., Three-dimensional profilometry based on shift estimation of projected fringe patterns, Applied Optics, 45, 4, pp. 678-687, (2006)