Absorbed dose, effective dose and lifetime attributable risk of breast and thyroid cancers in coronary CT angiography: A comparison between 64 and 128 slice CT scanners

被引:0
作者
Mirzaie, Ehsan [1 ]
Jafari, Salman [2 ]
Hadei, Seyed Kamaledin [3 ]
Nikzad, Safoora [4 ]
机构
[1] Hamadan Univ Med Sci, Sch Med, Hamadan, Iran
[2] Hamadan Univ Med Sci, Sch Paramed, Dept Radiol Technol, Hamadan, Iran
[3] Hamadan Univ Med Sci, Sch Med, Dept Radiol, Hamadan, Iran
[4] Hamadan Univ Med Sci, Sch Med, Dept Med Phys, Hamadan, Iran
关键词
Cancer; Coronary CT angiography; Breast; Thyroid; Absorbed dose; Thermoluminescence dosimetry; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; IMAGE QUALITY; REDUCTION; THORAX;
D O I
10.1016/j.radphyschem.2024.111845
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The attentive consideration of absorbed dose impact on the breast, a radiosensitive organ, remains pivotal in coronary computed tomography angiography (CCTA). Additionally, the thyroid is subjected to scatter radiation during this diagnostic procedure. The primary objective of this study was to comprehensively investigate and quantify the absorbed dose, effective dose, and lifetime attributable risks (LARs) associated with breast and thyroid cancers in the context of CCTA. This investigation enrolled a cohort of 180 patients (90 men and 90 women) who underwent CCTA utilizing three distinct CT scanners: the SOMATOM Definition AS 128 slice (Siemens 128), the Lightspeed VCT 64 Slice (GE 64), and the Brilliance 64 Slice (Philips 64). The precise quantification of absorbed doses to the breast and thyroid was achieved through the utilization of a thermoluminescence dosimeter (TLD). LAR for breast and thyroid cancers was evaluated in accordance with the BEIR VII report. Kruskal-Wallis test was employed to compare the means of absorbed doses and LARs. The average absorbed doses to the breast during CCTA with Siemens 128, GE 64, and Philips 64 scanners were 116.32 +/- 39.02, 82.88 +/- 18.33, and 84.11 +/- 15.18 mGy, respectively (P < 0.05). Correspondingly, the average LAR for breast cancer was found to be 84, 68, and 52 cases per 100,000 persons, respectively. Notably, a significant discrepancy in breast cancer LARs was observed among different age groups (P < 0.05). Regarding thyroid doses with Siemens 128, GE 64, and Philips 64 scanners, average values were 11.82 +/- 7.51, 12.20 +/- 10.87, and 14.49 +/- 5.43 mGy, respectively (P > 0.05). Additionally, the average LAR for thyroid cancer was determined as 0.32, 0.56, and 0.22 cases per 100,000 persons, respectively. Across all age groups, the LAR for thyroid cancer exhibited higher values among women compared to men. However, these differences did not achieve statistical significance (P > 0.05), indicating a need for further investigation. The findings prominently indicated high absorbed doses to the breast in CCTA using protocols investigated in this study (with an average of 93.7 +/- 30.26 mGy). Particularly, the LAR for breast cancer was higher among younger women, specifically those aged between 20 and 40 years (249 cases per 100,000). These results underscore the necessity for further justification and optimization of CCTA protocols.
引用
收藏
页数:6
相关论文
共 42 条
[21]   Organ Doses, Effective Dose, and Cancer Risk From Coronary CT Angiography Examinations [J].
Mahmoodi, Maede ;
Chaparian, Ali .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (05) :1131-1136
[22]   The diagnostic accuracy of coronary computed tomography angiography in patients with and without previous coronary interventions [J].
Mansour, Husam H. ;
Alajerami, Yasser S. ;
Abushab, Khaled M. ;
Quffa, Khetam M. .
JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (01) :81-86
[23]   Absorbed Radiation Dose in Radiosensitive Organs During Coronary CT Angiography Using 320-MDCT: Effect of Maximum Tube Voltage and Heart Rate Variations [J].
Nikolic, Boris ;
Khosa, Faisal ;
Lin, Pei-Jan Paul ;
Khan, Atif N. ;
Sarwar, Sheryar ;
Yam, Chun-Shan ;
Court, Laurence E. ;
Raptopoulos, Vassilios ;
Clouse, Melvin E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :1347-1354
[24]   Does Iterative Reconstruction Lower CT Radiation Dose: Evaluation of 15,000 Examinations [J].
Noel, Peter B. ;
Renger, Bernhard ;
Fiebich, Martin ;
Muenzel, Daniela ;
Fingerle, Alexander A. ;
Rummeny, Ernst J. ;
Dobritz, Martin .
PLOS ONE, 2013, 8 (11)
[25]  
Page P, 2014, INT J SPORTS PHYS TH, V9, P726
[26]   Cardiac Imaging Trends from 2010 to 2019 in the Medicare Population [J].
Reeves, Russell A. ;
Halpern, Ethan J. ;
Rao, Vijay M. .
RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (05)
[27]  
S Jafari, 2020, J Biomed Phys Eng, V10, P792, DOI 10.31661/jbpe.v0i0.2004-1099
[28]   A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner [J].
Sabarudin, Akmal ;
Siong, Tiong Wei ;
Chin, Ang Wee ;
Hoong, Ng Kwan ;
Karim, Muhammad Khalis Abdul .
SCIENTIFIC REPORTS, 2019, 9 (1)
[29]  
Sadeghi M, 2015, J Biomed Phys Eng, V5, P217
[30]   Efficiency of non-lead and lead thyroid shields in radiation protection of CT examinations [J].
Saeedi-Moghadam, Mahdi ;
Tayebi, Mansour ;
Chegeni, Nahid ;
Sina, Sedigheh ;
Kolayi, Tayebeh .
RADIATION PHYSICS AND CHEMISTRY, 2021, 180