Partial discharge detection with high-frequency band through resistance-temperature sensor of hydro power generator stator windings

被引:0
|
作者
Central Research Institute of Electric Power Industry, 2-6-1, Nagasaka, Yokosuka [1 ]
240-0196, Japan
不详 [2 ]
459-8522, Japan
机构
来源
IEEJ Trans. Power Energy | / 4卷 / 259-264期
关键词
Engineering Village;
D O I
暂无
中图分类号
学科分类号
摘要
Continuous Wavelet Transform - Continuous wavelet transforms - Generator - Generator stator windings - Insulation diagnosis - Partial discharge detection - Resistance temperature detectors - Resistance temperature sensor
引用
收藏
相关论文
共 50 条
  • [1] Partial Discharge Detection with High-Frequency Band through Resistance-Temperature Sensor of Hydropower Generator Stator Windings
    Kanegami, Masaki
    Miyazaki, Satoru
    Miyake, Katsuyuki
    ELECTRICAL ENGINEERING IN JAPAN, 2016, 195 (04) : 9 - 15
  • [2] Development of Portable Partial Discharge Monitor for Generator Stator Windings in Hydro Power Stations
    Kazuyoshi, Hozan
    Kazushi, Fukao
    Honda, Seiji
    Kaneko, Masahiko
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 814 - 816
  • [3] Partial discharge measurements on hydro generator stator windings case studies
    Li, Shunyuan
    Chow, Jennifer M. Y.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2007, 23 (03) : 5 - 15
  • [4] High frequency model for the analysis of partial discharge propagation along generator stator windings
    Major, S
    Su, Q
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 292 - 295
  • [5] Effects of Frequency and Temperature on Partial Discharge Characterization of Stator Windings
    Kantar, Emre
    Eberg, Espen
    Hvidsten, Sverre
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 369 - 373
  • [6] Propagation mode and speed of partial discharge pulse through the stator windings of turbine generator
    Jiang, JG
    Liu, DH
    Deng, H
    Cao, HX
    Zhao, ZM
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 192 - 196
  • [7] Field detection of ultra-wide band partial discharge for generator stator insulation
    Chen, Xiao-Lin
    Cao, Xu-Ping
    Lu, Yi-Hang
    Yue, Bo
    Cheng, Yong-Hong
    Xie, Heng-Kun
    Zhongguo Dianli/Electric Power, 2002, 35 (03):
  • [8] Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windings
    Emery, FT
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 347 - 361
  • [9] The directionality of an optical fiber high-frequency acoustic sensor for partial discharge detection and location
    Zhao, ZQ
    MacAlpine, M
    Demokan, MS
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2000, 18 (06) : 795 - 806
  • [10] Analysis of Partial Discharge Activity for Evaluation of the State of High Power Electric Generators Stator Windings
    Sorin, Dumitrescu
    PROBLEMELE ENERGETICII REGIONALE, 2016, (02): : 29 - 38