Seasonal performance evaluation of refrigeration equipment used for subway train air-conditioning systems

被引:0
作者
Liu, Xin [1 ]
Zhou, Yuanlong [1 ]
Bi, Haiquan [1 ]
Lin, Congyun [1 ]
Li, Ce [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610031, Peoples R China
关键词
Subway train; Refrigeration equipment; Air-conditioning system; Seasonal energy efficiency ratio; Seasonal performance evaluation; ENERGY-EFFICIENCY STANDARDS; THERMOSIPHON; ECONOMIZERS; SAVINGS; CHINA; WORK; RAIL;
D O I
10.1016/j.applthermaleng.2024.125253
中图分类号
O414.1 [热力学];
学科分类号
摘要
Seasonal performance evaluation of refrigeration equipment used for air-conditioning is to evaluate the comprehensive refrigeration capacity of the air-conditioning system throughout the refrigeration season. Different load characteristics and air-conditioning equipment make the simplification and abstraction methods of seasonal performance indicators different. There are great differences in the operating environment, service time range, and air-conditioning performance characteristics between train air-conditioning and building airconditioning. In order to describe the comprehensive cooling capacity of subway train air-conditioning during the whole cooling season, this study proposes a specific method for evaluating the seasonal performance of the subway train air-conditioning systems under the condition of an air-conditioning bench test. This study first analyzes the construction methods of the typical cooling load model, the running time distribution model, and the performance model of the subway train air-conditioning systems. Then, the specific calculation formulas of seasonal energy efficiency ratio (SEER) are proposed for three common operation forms of subway train airconditioning systems, which are two-compressor fixed-frequency air-conditioning systems, four-compressor fixed-frequency air-conditioning systems, and two-compressor variable-frequency air-conditioning systems, by means of numerical simulation and mathematical derivation. Finally, the real SEER is calculated based on the energy consumption test value for the two-compressor fixed-frequency air-conditioning system. Compared with the real SEER, the relative error of SEERcal obtained by the SEER calculation method proposed in this study is less than 5%, which indicates that the seasonal performance evaluation of refrigeration equipment used for subway train air-conditioning systems is highly accurate.
引用
收藏
页数:16
相关论文
共 49 条
[1]   Thermal analysis of AA7075-AA7072/methanol via Williamson hybrid nanofluid model past thin needle: Effects of Lorentz force and irregular heat rise/fall [J].
Abbas, Amir ;
Hussanan, Abid ;
Anwar, Fizza ;
Obalalu, Adebowale Martins ;
Almeshaal, Mohammed A. ;
Palaniappan, Murugesan ;
Choubani, Karim ;
Kolsi, Lioua ;
Aslam, Muhammad .
CASE STUDIES IN THERMAL ENGINEERING, 2024, 53
[2]   Effect of non-uniform heat rise/fall and porosity on MHD Williamson hybrid nanofluid flow over incessantly moving thin needle [J].
Abbas, Amir ;
Hussanan, Abid ;
Obalalu, Adebowale Martins ;
Kriaa, Karim ;
Maatki, Chemseddine ;
Hadrich, Bilel ;
Aslam, Muhammad ;
Kolsi, Lioua .
HELIYON, 2024, 10 (01)
[3]   Numerical simulation of variable density and magnetohydrodynamics effects on heat generating and dissipating Williamson Sakiadis flow in a porous space: Impact of solar radiation and Joule heating [J].
Abbas, Amir ;
Khan, Aziz ;
Abdeljawad, Thabet ;
Aslam, Muhammad .
HELIYON, 2023, 9 (11)
[4]   Air-conditioning Energy-saving Control Strategy at Subway Station Based on MAS Evolutionary Algorithm [J].
An Yanping ;
Qian Ping .
PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA 2015), 2015, :122-125
[5]  
[Anonymous], 1998, ARI550/590-1998
[6]  
[Anonymous], 2010, GB/T 17758-2010
[7]  
[Anonymous], 1988, TB/T 1951-87
[8]  
[Anonymous], 2008, GB/T 21455-2008
[9]  
[Anonymous], 2017, TB/T 1804-2017
[10]  
[Anonymous], 2005, JRA 4055