Clinical evaluation of performance, stability, and longevity of an accelerator system designed for boron neutron capture therapy utilising a beryllium target

被引:0
|
作者
Hu, Naonori [1 ,2 ]
Kakino, Ryo [1 ]
Sasaki, Akinori [1 ]
Yoshikawa, Syuushi [3 ]
Akita, Kazuhiko [1 ]
Takeno, Satoshi [1 ,4 ]
Yoshino, Yuki [1 ,4 ,5 ]
Aihara, Teruhito [1 ,6 ]
Nihei, Keiji [1 ,4 ]
Nojiri, Mai [7 ]
Matsubayashi, Nishiki [2 ]
Takata, Takushi [2 ]
Tanaka, Hiroki [2 ]
Suzuki, Minoru [2 ]
Ono, Koji [3 ]
机构
[1] Osaka Med & Pharmaceut Univ, Kansai BNCT Med Ctr, Takatsuki, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Kyoto, Japan
[3] Osaka Med & Pharmaceut Univ, BNCT Joint Clin Inst, Osaka, Japan
[4] Osaka Med & Pharmaceut Univ Hosp, Dept Radiat Oncol, Osaka, Japan
[5] Kyoto Prefectural Univ Med, Dept Radiol, Kyoto, Japan
[6] Osaka Med & Pharmaceut Univ Hosp, Dept Otorhinolaryngol, Osaka, Japan
[7] Kyoto Univ, Grad Sch Engn, Dept Nucl Engn, Kyoto, Japan
关键词
Boron neutron capture therapy; Cyclotron-accelerator; Beryllium target; Neutron measurement; Stability;
D O I
10.1016/j.nima.2024.170126
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Boron neutron capture therapy for recurrent head and neck cancer has been approved as an insurance covered treatment in Japan since June 2020. The Kansai BNCT Medical Center has installed the NeuCure (R) BNCT system developed by Sumitomo Heavy Industries. This system utilises a beryllium target with a 30 MeV proton beam to generate neutrons. To date, the center has treated over 300 patients and the system is also used for quality control and fundamental research experiments. Information on the stability and longevity of the system is important for facilities and hospitals considering installation of a BNCT system in the future, particularly after an exchange of a major component, such as the target. The beam output (neutron and gamma ray) was measured before and after the exchange of the target. The thermal neutron, fast neutron and gamma ray distribution inside a water phantom was evaluated and the results showed no significant change in the beam quality after the exchange of the target. Furthermore, no significant change in the neutron flux as a function of increasing number of accumulated protons on the target was observed up to a value of just under 400 mAh. The NeuCure (R) BNCT system has been shown to be highly stable and the frequency of target replacement was much less than lithium target-based accelerators.
引用
收藏
页数:7
相关论文
共 18 条
  • [1] Development of beryllium-based neutron target system with three-layer structure for accelerator-based neutron source for boron neutron capture therapy
    Kumada, Hiroaki
    Kurihara, Toshikazu
    Yoshioka, Masakazu
    Kobayashi, Hitoshi
    Matsumoto, Hiroshi
    Sugano, Tomei
    Sakurai, Hideyuki
    Sakae, Takeji
    Matsumura, Akira
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 78 - 83
  • [2] Development of a high-power water cooled beryllium target for use in accelerator-based boron neutron capture therapy
    Blackburn, BW
    Yanch, JC
    Klinkowstein, RE
    MEDICAL PHYSICS, 1998, 25 (10) : 1967 - 1974
  • [3] Evaluation of heat removal performance of a sealed Li target for an accelerator-driven neutron source of Boron Neutron Capture Therapy at Nagoya University
    Honda, Shogo
    Yoshihashi, Sachiko
    Hamaji, Yukinori
    Shen, Jingjie
    Tsuchida, Kazuki
    Nishitani, Takeo
    Kiyanagi, Yoshiaki
    Tsurita, Yukio
    Watanabe, Kenichi
    Yamazaki, Atsushi
    Uritani, Akira
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042
  • [4] Long-term beam output stability of an accelerator-based boron neutron capture therapy system
    Komori, Shinya
    Takeuchi, Akihiko
    Kato, Ryohei
    Yamazaki, Yuhei
    Motoyanagi, Tomoaki
    Narita, Yuki
    Kato, Takahiro
    Takai, Yoshihiro
    MEDICAL PHYSICS, 2024, : 9250 - 9263
  • [5] Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study
    Cheon, Bo-Wi
    Yoo, Dohyeon
    Park, Hyojun
    Lee, Hyun Cheol
    Shin, Wook-Geun
    Choi, Hyun Joon
    Hong, Bong Hwan
    Chung, Heejun
    Min, Chul Hee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (06) : 1970 - 1978
  • [6] Evaluation of moderator assemblies for use in an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1998, 123 (03) : 320 - 334
  • [7] Development of a Sealed Li target as an accelerator-driven neutron source for Boron neutron capture therapy at Nagoya University
    Honda, Shogo
    Yoshihashi, Sachiko
    Tomita, Seinosuke
    Tsuchida, Kazuki
    Kiyanagi, Yoshiaki
    Tsurita, Yukio
    Watanabe, Kenichi
    Yamazaki, Atsushi
    Uritani, Akira
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [9] Evaluation of calculation accuracy and computation time in a commercial treatment planning system for accelerator-based boron neutron capture therapy
    Takeuchi, Akihiko
    Hirose, Katsumi
    Kato, Ryohei
    Komori, Shinya
    Sato, Mariko
    Motoyanagi, Tomoaki
    Yamazaki, Yuhei
    Narita, Yuki
    Takai, Yoshihiro
    Kato, Takahiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (04) : 907 - 917
  • [10] Design of Beam Shaping Assembly for Accelerator-based Boron Neutron Capture Therapy and Study on Its Clinical Parameter
    Wang Y.
    Wang Z.
    Li N.
    Guan X.
    Gu L.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (07): : 1440 - 1447