Design and analysis of a novel natural gas liquefaction process based on two-stage ejector-expansion refrigeration cycle

被引:0
|
作者
Pan, Jie [1 ,2 ]
Li, Yuanyuan [1 ]
Cao, Qinghan [1 ]
Wang, Jiale [3 ]
Li, Ran [1 ]
机构
[1] Xian Shiyou Univ, Coll Petr Engn, Xian 710065, Peoples R China
[2] Xian Shiyou Univ, Univ Shaanxi Prov, Engn Res Ctr Safety & Energy Saving Oil & Gas Stor, Xian 710065, Peoples R China
[3] Shaanxi Yanchang Petr Grp Co Ltd, Nat Gas Res Inst, Xian 710065, Peoples R China
关键词
Natural gas liquefaction; Ejector; Two-stage cycle refrigeration; Thermodynamic analysis; Thermo-economic analysis; ADVANCED EXERGOECONOMIC ANALYSIS; VAPOR COMPRESSION REFRIGERATION; CO2; RANKINE-CYCLE; LNG COLD ENERGY; MULTIOBJECTIVE OPTIMIZATION; ECONOMIC-ANALYSIS; THERMOECONOMIC OPTIMIZATION; ENVIRONMENTAL-ANALYSES; POWER CYCLE; SYSTEM;
D O I
10.1016/j.fuel.2024.134004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a novel natural gas liquefaction process based on two-stage ejector-expansion refrigeration cycle (T-EERC). Specific energy consumption, exergy efficiency, liquefaction ratio, and total cost rate indexes are applied to evaluate the process. Subsequently, energy, exergy, economic, exergoenvironmental, and exergoeconomic analysis are performed to the T-EERC process. The T-EERC process is capable of producing 47.21 kg/ s of liquefied natural gas (LNG), with a specific energy consumption of 0.2336 kWh/kg, an exergy efficiency of 57.95 %, a liquefaction ratio of 62.94 % and a total cost rate of 0.1562 M$/year, offers a better performance than other natural gas liquefaction processes. The system sensitivity analysis indicates that an increase in the high pressure inlet of the ejector leads to an increase in specific energy consumption for the system and a decrease in exergy efficiency. The energy analysis shows that the heat exchanger HX1 exhibits the lowest energy loss and the maximum heat transfer efficiency. From the exergy analysis, it is found that the total exergy destruction is 30867.43 kW and the greatest exergy destruction was associated with the heat exchangers, the throttles and the compressors. The economic analysis suggests that the total cost rate is more sensitive to fluctuations in the annual interest rate. The exergoenvironmental analysis indicates that the system operates at higher temperatures with less environmental impact. From an exergoeconomic perspective, the maximum cost rate of exergy destruction (720.95$/h) is related to HX5. Furthermore, the exergoeconomic factor of heat exchangers is typically minimal, necessitating supplementary financial outlay to enhance their performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Thermodynamic analysis of a novel multi-target temperature transcritical CO2 ejector-expansion refrigeration cycle with vapor-injection
    Zeng, Min-Qiang
    Zheng, Qiu-Yun
    Zhang, Xue-Lai
    Mo, Fan-Yang
    Zhang, Xin-Rong
    ENERGY, 2022, 259
  • [32] ENERGETIC AND ENTROPY ANALYSIS OF A NOVEL TRANSCRITICAL CO2 TWO-STAGE COMPRESSION/EJECTOR REFRIGERATION CYCLE FOR SHIPBOARD COLD CHAMBER
    Yang, Dazhang
    Li, Yang
    Xie, Jing
    Wang, Jinfeng
    THERMAL SCIENCE, 2023, 27 (4A): : 2607 - 2621
  • [33] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    Bai, Tao
    Lu, Yu
    Yan, Gang
    Yu, Jianlin
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (06) : 2015 - 2026
  • [34] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    Tao Bai
    Yu Lu
    Gang Yan
    Jianlin Yu
    Journal of Thermal Science, 2021, 30 : 2015 - 2026
  • [35] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    BAI Tao
    LU Yu
    YAN Gang
    YU Jianlin
    JournalofThermalScience, 2021, 30 (06) : 2015 - 2026
  • [36] Optimal design of a two-stage refrigeration cycle for natural gas pre-cooling in a gas refinery considering the best allocation of refrigerant
    Tahmasebzadehbaie, Mohammad
    Sayyaadi, Hoseyn
    ENERGY CONVERSION AND MANAGEMENT, 2020, 210
  • [37] Thermodynamic analysis and optimization of novel ejector-expansion TRCC (transcritical CO2) cascade refrigeration cycles (Novel transcritical CO2 cycle)
    Yari, Mortaza
    Mahmoudi, S. M. S.
    ENERGY, 2011, 36 (12) : 6839 - 6850
  • [38] Optimization on ejector key geometries of a two-stage ejector-based multi evaporator refrigeration system
    Yan, Jia
    Wen, Na
    Wang, Ling
    Li, Xianbi
    Liu, Zhan
    Li, Shengyu
    ENERGY CONVERSION AND MANAGEMENT, 2018, 175 : 142 - 150
  • [39] Thermodynamics analysis of a modified dual-evaporator CO2 transcritical refrigeration cycle with two-stage ejector
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY, 2015, 84 : 325 - 335
  • [40] Experimental investigation on a transcritical CO2 ejector expansion refrigeration system with two-stage evaporation
    Zheng, Lixing
    Deng, Jianqiang
    APPLIED THERMAL ENGINEERING, 2017, 125 : 919 - 927