Modified tuna swarm optimization algorithm for brain stroke imaging with electrical impedance tomography

被引:3
作者
Lou, Yajun [1 ]
Shi, Yanyan [2 ,3 ]
Yang, Ke [2 ]
Zhou, Lu [1 ]
Yang, Tianyi [1 ]
Zhang, Peng [1 ]
Qin, Bing [1 ]
Qian, Zhiyu [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Dept Biomed Engn, Key Lab Digital Med Equipment & Technol Jiangsu Pr, Nanjing 210016, Peoples R China
[2] Henan Normal Univ, Coll Elect & Elect Engn, Xinxiang 453007, Peoples R China
[3] Fourth Mil Med Univ, Fac Biomed Engn, Xian 710032, Peoples R China
基金
中国国家自然科学基金;
关键词
Stroke; Electrical impedance tomography; Boundary voltage data; Algorithm; Image reconstruction; INTRACEREBRAL HEMORRHAGE; QUALITY; MODELS; INJURY; EIT;
D O I
10.1016/j.enganabound.2024.105786
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Stroke is a common disease characterized by high disability rate and high mortality rate. Accurate detection and continuous monitoring are vital for the treatment of stroke. As a promising medical imaging technique, electrical impedance tomography (EIT) is able to provide an alternative for brain imaging. With this technique, conductivity distribution variation caused by pathological change can be visualized. However, image reconstruction is a severely ill-posed inverse problem. Particularly in brain imaging, irregular and multi-layered head structure along with low-conductivity skull further aggravate the challenge for accurate reconstruction. To solve this problem, a novel image-reconstruction method based on modified tuna swarm optimization is proposed for visualizing the conductivity distribution in brain EIT. To evaluate the performance of the proposed method, extensive simulations are carried out on a three-layer head model. The anti-noise performance of the proposed method is estimated by considering noise with different signal-to-noise ratios. In addition to simulation, phantom experiments are conducted to further verify the effectiveness of the proposed method. Both reconstructed images and quantitative evaluations demonstrate that the proposed approach performs well in the reconstruction of simulated intracerebral hemorrhage and secondary ischemia. This work would offer an alternative for accurate reconstruction in medical imaging based on EIT.
引用
收藏
页数:12
相关论文
共 43 条
[1]   Electrical Impedance Tomography: Tissue Properties to Image Measures [J].
Adler, Andy ;
Boyle, Alistair .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (11) :2494-2504
[2]   Detection of small bleeds in the brain with electrical impedance tomography [J].
Boverman, Gregory ;
Kao, Tzu-Jen ;
Wang, Xin ;
Ashe, Jeffrey M. ;
Davenport, David M. ;
Amm, Bruce C. .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) :727-750
[3]   Approximation error method for imaging the human head by electrical impedance tomography* [J].
Candiani, V ;
Hyvonen, N. ;
Kaipio, J. P. ;
Kolehmainen, V .
INVERSE PROBLEMS, 2021, 37 (12)
[4]   MULTI-STRATEGY IMPROVED TUNA SWARM OPTIMIZATION (TSO)-BASED HYBRID KERNEL EXTREME LEARNING MACHINE MODEL FOR EARLY DIAGNOSIS OF PARKINSON'S DISEASE [J].
Chen, Hong .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (08)
[5]   Stroke Risk Prediction With Hybrid Deep Transfer Learning Framework [J].
Chen, Jie ;
Chen, Yingru ;
Li, Jianqiang ;
Wang, Jia ;
Lin, Zijie ;
Nandi, Asoke K. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (01) :411-422
[6]   Hybrid Learning-Based Cell Aggregate Imaging With Miniature Electrical Impedance Tomography [J].
Chen, Zhou ;
Yang, Yunjie ;
Bagnaninchi, Pierre-Olivier .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
[7]   ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
CHENG, KS ;
ISAACSON, D ;
NEWELL, JC ;
GISSER, DG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) :918-924
[8]   Intracerebral haemorrhage: current approaches to acute management [J].
Cordonnier, Charlotte ;
Demchuk, Andrew ;
Ziai, Wendy ;
Anderson, Craig S. .
LANCET, 2018, 392 (10154) :1257-1268
[9]   Maximum entropy regularization method for electrical impedance tomography combined with a normalized sensitivity map [J].
Fan, W. R. ;
Wang, H. X. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (03) :277-283
[10]  
Gondro C, 2007, GENET MOL RES, V6, P964