Transient stability assessment using equal area criterion based on generator terminal voltage

被引:0
作者
Shimizu K. [1 ]
Yamamoto K. [2 ]
Ishigame A. [2 ]
机构
[1] Kansai Electric Power Co., Inc., R&D Center, 3-11-20, Nakoji, Amagasaki
[2] Osaka Prefecture University, 1-1, Gakuen-cho, Naka-ku, Sakai
关键词
Out-of-step condition prediction; Power angle equation; Power system stability; Stability analysis; Transient stability;
D O I
10.1541/ieejpes.140.780
中图分类号
学科分类号
摘要
Equal area criterion is frequently used as a means to assess transient stability. The method can be hardly applied to observed data because the method is based on rotor angles which need to be measured with specially deployed sensors. This paper presents the equal area criterion using generator terminal voltages instead of the rotor angles. It is easy to measure the voltages, thus the novel method would be more acceptable to industry. © 2020 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:780 / 781
页数:1
相关论文
共 50 条
[21]   Using Critical Machine Couple Equal Area Criterion To Assess Multi-machine System Stability [J].
Lu Fang ;
Yu Ji-lai .
2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, :1896-1899
[22]   Measurement-Based Voltage Stability Assessment Considering Generator VAR Limits [J].
Liu, Chengxi ;
Hu, Fengkai ;
Shi, Di ;
Zhang, Xiaohu ;
Sun, Kai ;
Wang, Zhiwei .
IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) :301-311
[23]   Transient Voltage Recovery Control and Stability Criterion of VSC-Based DC Power Grid [J].
Zhang, Xiangyu ;
Shao, Xinyu ;
Fu, Yuan ;
Zhao, Xinyan ;
Jiang, Guowen .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (04) :3496-3506
[24]   Novel transient stability assessment using post-disturbance voltage fluctuations [J].
Shimizu, Koichiro ;
Ishigame, Atsushi .
2020 INTERNATIONAL CONFERENCE ON SMART GRIDS AND ENERGY SYSTEMS (SGES 2020), 2020, :12-17
[25]   Transient stability and voltage regulation in wide area power grid using switching controller [J].
Yang Chao ;
Cheng Xin-Ming ;
Liu Zhi-Wei ;
Ding Li ;
Guan Zhi-Hong .
2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, :8204-8209
[26]   Effect of the generators tripping in the transient stability of an electrical power system using the extended equal area criteria [J].
Ferreira, CMM ;
Pinto, JAD ;
Barbosa, FPM .
POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, :1295-1299
[27]   Wide Area Synchrophasor Measurements based Transient Stability Assessment and Emergency Control [J].
Siddiqui, Shahbaz. A. ;
Verma, Kusum ;
Niazi, K. R. ;
Fozdar, Manoj .
2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
[28]   Hybrid voltage stability and security assessment using synchrophasors with consideration of generator Q-limits [J].
Hur Rizvi, Syed Muhammad ;
Kundu, Pratim ;
Srivastava, Anurag K. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (19) :4042-4051
[29]   Improving transient stability using generator tripping based on tracking rotor-angle [J].
Karady, GG ;
Kattamesh, MA .
2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2002, :1113-1118
[30]   Nonlinear Modeling and Stability Analysis of Grid-Tied Paralleled-Converters Systems Based on the Proposed Dual-Iterative Equal Area Criterion [J].
Li, Xilin ;
Tian, Zhen ;
Zha, Xiaoming ;
Sun, Pengfei ;
Hu, Yufei ;
Huang, Meng ;
Sun, Jianjun .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (06) :7746-7759