Transient stability assessment using equal area criterion based on generator terminal voltage

被引:0
|
作者
Shimizu K. [1 ]
Yamamoto K. [2 ]
Ishigame A. [2 ]
机构
[1] Kansai Electric Power Co., Inc., R&D Center, 3-11-20, Nakoji, Amagasaki
[2] Osaka Prefecture University, 1-1, Gakuen-cho, Naka-ku, Sakai
关键词
Out-of-step condition prediction; Power angle equation; Power system stability; Stability analysis; Transient stability;
D O I
10.1541/ieejpes.140.780
中图分类号
学科分类号
摘要
Equal area criterion is frequently used as a means to assess transient stability. The method can be hardly applied to observed data because the method is based on rotor angles which need to be measured with specially deployed sensors. This paper presents the equal area criterion using generator terminal voltages instead of the rotor angles. It is easy to measure the voltages, thus the novel method would be more acceptable to industry. © 2020 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:780 / 781
页数:1
相关论文
共 50 条
  • [1] Transient Stability Assessment Using Individual Machine Equal Area criterion Part II: Stability Margin
    Wang, Songyan
    Yu, Jilai
    Zhang, Wei
    IEEE ACCESS, 2018, 6 : 38693 - 38705
  • [2] Transient Stability Assessment Using Individual Machine Equal Area Criterion PART III: Reference Machine
    Wang, Songyan
    Yu, Jilai
    Zhang, Wei
    IEEE ACCESS, 2019, 7 : 80174 - 80193
  • [3] Transient Stability Assessment Using Individual Machine Equal Area Criterion PART I: Unity Principle
    Wang, Songyan
    Yu, Jilai
    Zhang, Wei
    IEEE ACCESS, 2018, 6 : 77065 - 77076
  • [4] Transient Stability Analysis with Equal Area Criterion Directly Used to a Non-Equivalent Generator Pair
    Lu Fang
    Yu Ji-Lai
    2009 INTERNATIONAL CONFERENCE ON POWER ENGINEERING, ENERGY AND ELECTRICAL DRIVES, 2009, : 375 - 378
  • [5] A Priori Transient Stability Indicator of Islanded Power Systems using Extended Equal Area Criterion
    McNabb, Patrick
    Bialek, Janusz
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [6] Energy-Based Reinterpretation of Equal Area Criterion for Generator Instability Assessment via Local Rotational Speed and Voltage Frequency Measurements
    Kim, Jongju
    IEEE ACCESS, 2025, 13 : 47748 - 47762
  • [7] A Preventive Transient Stability Control Strategy Through Individual Machine Equal Area Criterion Framework
    Batchu, Sreenadh
    Teeparthi, Kiran
    IEEE ACCESS, 2021, 9 : 167776 - 167794
  • [8] An Improved Equal Area Criterion for Transient Stability Analysis of Converter-Based Microgrid Considering Nonlinear Damping Effect
    Tang, Yingjie
    Tian, Zhen
    Zha, Xiaoming
    Li, Xilin
    Huang, Meng
    Sun, Jianjun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (09) : 11272 - 11284
  • [9] Transient Stability Evaluation by the Time Domain Equal-area Criterion Using the Taylor Series Expansion
    Sadakawa, Tomomi
    Sato, Ako
    Tanabe, Ryu
    Iwamoto, Shinichi
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 66 - 71
  • [10] Hybrid extended equal-area criterion for fast transient stability assessment with detailed power system models
    Zhang, Y
    Rousseaux, P
    Wehenkel, L
    Pavella, M
    Xue, Y
    Meyer, B
    Trotignon, M
    CONTROL OF POWER PLANTS AND POWER SYSTEMS (SIPOWER'95), 1996, : 49 - 54