Analysis on mis-operation of zero-sequence differential and phase differential protection for three-phase compact auto-transformer using ANSYS

被引:0
|
作者
Wang, Zhien [1 ,2 ]
Suonan, Jiale [2 ]
Jiao, Zaibin [2 ]
Qin, Qin [3 ]
机构
[1] Guangzhou Bureau of CSG EHV Power Transmission Company, Guangzhou 510405, China
[2] School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
[3] Shaanxi Electric Power Corporation, Xi'an 710048, China
来源
Dianli Xitong Zidonghua/Automation of Electric Power Systems | 2013年 / 37卷 / 05期
关键词
Electric instrument transformers;
D O I
10.7500/AEPS201205059
中图分类号
学科分类号
摘要
引用
收藏
页码:130 / 133
相关论文
共 38 条
  • [1] Simulation Study on the Unbalanced Operation Characteristics of a Three-Phase Auto-Transformer with Asymmetrical Winding Parameters
    Chen, Liangyuan
    2017 INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS, ELECTRONICS AND CONTROL (ICCSEC), 2017, : 193 - 195
  • [2] Analysis of magnetic inrush current of three-phase transformer and the differential protection scheme
    Beijing Sifang Automation Co. Ltd., Beijing 100083, China
    Dianli Xitong Zidonghue, 2006, 10 (58-60):
  • [3] Zero-sequence differential protection scheme for a converter transformer based on waveform correlation analysis
    Luo M.
    Guo X.
    Yu X.
    Wu J.
    He J.
    Shou H.
    Zheng T.
    Li L.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (12): : 80 - 89
  • [4] Zero-sequence current differential phase selection based on three-sequence differential currents similar principle
    Liu, Huanzhang
    Wang, Xingguo
    Li, Ming
    Zhou, Zexin
    Du, Dingxiang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (16): : 92 - 95
  • [5] Optimizing the operation of current differential protection by power differential relay for three phase transformer
    Bahmani, B
    Nafar, M
    Ranjbar, AM
    Proceedings of the 4th WSEAS International Conference on Applications of Electrical Engineering, 2005, : 378 - 383
  • [6] A Novel Scheme for UHV Auto-Transformer Phase Comparison Longitudinal Protection Principle Based on Zero Sequence Current
    Kader, Alimjan
    Dong, Xinzhou
    Wang, Hai-Yun
    Arken, Yiliyar
    INTERNATIONAL CONFERENCE ON ELECTRONIC AND ELECTRICAL ENGINEERING (CEEE 2014), 2014, : 268 - 275
  • [7] Zero-Sequence Differential Current Protection Scheme for Converter Transformer Based on Waveform Correlation Analysis
    Zheng, Tao
    Yang, Xinhui
    Guo, Xingchao
    Wang, Xingguo
    Zhang, Chengqi
    ENERGIES, 2020, 13 (07)
  • [8] Countermeasures for Mal-operation of Zero-sequence Differential Protection of Converter Transformer Under Inrush Current Condition
    Weng H.
    Guo Y.
    Li H.
    Wan Y.
    Li Z.
    Huang J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (23): : 143 - 149
  • [9] Zero-Sequence current measurement uncertainty in three-phase power systems during normal operation
    Nauta, Sjoerd
    Serra, Ramiro
    IET Generation, Transmission and Distribution, 2021, 15 (24): : 3450 - 3458
  • [10] Mechanism and countermeasures of mal-operation of converter transformer zero-sequence differential protection under special conditions
    Weng H.
    Li H.
    Wan Y.
    Li Z.
    Huang J.
    Lin X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (05): : 56 - 64