Novel dissolved oxygen distribution model of a full-scale aeration tank for a municipal wastewater treatment plant in a cold climate region

被引:1
作者
Ukkonen, Petri [1 ]
Mulas, M. [1 ,2 ]
Mikola, A. [1 ]
机构
[1] Aalto Univ, Dept Build Environm, Tietotie 1 E, Espoo 02150, Finland
[2] Univ Fed Ceara, Dept Teleinformat Engn, Campus Pici, Fortaleza, Brazil
关键词
aeration; CFD; climate change; dissolved oxygen; wastewater; WWTP; BUBBLE-COLUMN; FLOW; SYSTEMS;
D O I
10.2166/wcc.2024.667
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Aeration is the most energy-intensive process in wastewater treatment plants (WWTP). Seasonal variation in hydraulic flow and load has a significant effect on WWTP's aeration energy efficiency. High flow and temperature variations are common in cold climate regions, and with climate change increasing extreme weather events will accentuate these situations. The prediction of oxygen mass transfer is crucial for minimizing the energy consumption of the aeration tank. This study presents a computational fluid dynamics model for a turbulent flow regime, simulating the hydraulics and dissolved oxygen (DO) concentration distribution of two phases, water and air bubbles, in a fullscale, as-built activated sludge tank. Model validation error was less than 15%. Different seasonal flows and temperatures were investigated by fixing liquid side oxygen mass transfer coefficient (kL) to 0.7x10(-5) m/s and initial bubble diameter (dB) to 0.0025 m in the gas phase. The results show that variating hydraulic flow causes noticeable differences in DO distribution and higher flow could be more effective levelling in DO gradients. More even DO distribution could result in using up to a 10% lower DO setpoint value, using 3% less air for the same treatment result, thus lowering aeration energy cost.
引用
收藏
页码:5698 / 5713
页数:16
相关论文
共 29 条
  • [1] Aeration control - a review
    Amand, L.
    Olsson, G.
    Carlsson, B.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2013, 67 (11) : 2374 - 2398
  • [2] [Anonymous], 2023, CFD MODULE COMSOL US
  • [3] [Anonymous], 2018, HSY
  • [4] [Anonymous], 2024, HSY
  • [5] Fuzzy Logic Based Dissolved Oxygen Control for SBR Wastewater Treatment Process
    Fan, Liping
    Boshnakov, Kosta
    [J]. 2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 4142 - 4146
  • [6] Oxygen transfer prediction in aeration tanks using CFD
    Fayolle, Yannick
    Cockx, Arnaud
    Gillot, Sylvie
    Roustan, Michel
    Heduit, Alain
    [J]. CHEMICAL ENGINEERING SCIENCE, 2007, 62 (24) : 7163 - 7171
  • [7] Grace, 1978, BUBBLES DROPS PARTIC
  • [8] Grady C.P. Leslie., 2011, Biological Wastewater Treatment, Third
  • [9] Gray M., 2011, P WATER ENV FEDERATI, V2011, P312, DOI [10.2175/193864711802836373, DOI 10.2175/193864711802836373]
  • [10] Effects of aeration patterns on the flow field in wastewater aeration tanks
    Gresch, Markus
    Armbruster, Martin
    Braun, Daniel
    Gujer, Willi
    [J]. WATER RESEARCH, 2011, 45 (02) : 810 - 818